background image

American English–5

1 609 929 E86  •  (02.12) T

  

Switching On/Off

Switching on:

Press the 

“on/off”

 button 

6

 or the measurement button 

7

 completely

down.

Switching off:

Press the 

“on/off”

 button 

6

.

After approx. 5 min without performing a measurement, the unit switches
off automatically to save the batteries.

With the automatic switch-off, the current display and the settings of the
unit are also stored in addition to the already stored measured values.
When switched on again, the unit is in the same function and shows the
same display as before the automatic switch-off.

Changing the Measuring Unit

After switching on the measuring instrument, the measured values are
shown in the unit that was selected the last time the measuring instrument
was used.

With repeated pressing of the “

m/ft

” button

10

, switching between the units of measure

shown here can be made at any time, also for
already calculated values.

Exception: If the continuous laser beam is
switched on (see 

Continuous Pointer Mode)

,

the measuring unit cannot be changed.

For areas or volume entries, only units of m or ft are possible.

Measuring Procedure

The instrument has several measuring functions that can be selected by
pressing the respective function button (see 

Measurement Functions

Section).  After switching on, the instrument is in the “Length Measuring”
function.

To change the measuring function, press the button for the desired func-
tion.  After selecting the measuring function, all further steps take place by
pressing the measure button 

7

.

Place the rear end of the unit (end piece) at the desired measuring position
(e.g. on a wall).  The rear end of the unit is the reference point for the mea-
surement.

To switch on the laser beam, lightly press the measurement button 

7

in the middle or press at the side.

Aim at the target.

Do not point the laser beam at persons or animals. 

To measure, press the measure button 

7

 completely down.

The measured value appears after 0.5 to 4 s.  The end of the measure-
ment is indicated by an acoustical signal.  The duration of the measure-
ment is dependent on the distance, light conditions and reflection charac-
teristics of the measured surface.  After completion of the measuring
procedure, the laser switches off automatically.

Putting into Operation

Summary of Contents for Precision HD150

Page 1: ...29 0635 3120 28 0635 1490 0600 1320 17 0600 1310 18 0600 1340 3 0600 1330 30...

Page 2: ...A B C E D F...

Page 3: ...3 16 1 2 5 7 8 4 9 11 12 14 13 15 6 4 10 17 18 19 19 a b c d e f g h i k l m...

Page 4: ...21 20 4 24 26 27 25 22 23...

Page 5: ...asuring Instrument Order number HD 150 Measuring range natural surfaces 0 3 150 m 1 500 ft Measuring accuracy Typical 0 3 30 m 1 100 ft Maximum 2 mm 3 32 in 3 mm 1 8 in Measuring time Typical Maximum...

Page 6: ...utton 3 Bubble level 4 Aligning aid 5 Area measurement button 6 on off button 7 Measurement button Two step button for sighting and measuring 8 Display 9 Display lighting button Symbols Symbol Name Me...

Page 7: ...Positioning extension 28 Laser viewing glasses 29 Target panel 30 Protective bag Accessory parts included Optional accessories not included Display Elements a Laser switched on b Measurement function...

Page 8: ...ever open the unit yourself Trimble is able to ensure perfect functioning of the unit only if the orig inal accessories intended for it are used Protect the unit from moisture and direct sunrays Dirt...

Page 9: ...For areas or volume entries only units of m or ft are possible Measuring Procedure The instrument has several measuring functions that can be selected by pressing the respective function button see M...

Page 10: ...m mea surement If possible rest the instrument on or against the measuring point The measurement takes place at the middle point of the light spot also for obliquely illuminated target surfaces The me...

Page 11: ...ece The unit takes automatically into consideration the different lengths of the end pieces when measuring measurement in both cases from the rear end of the unit Bubble Level The bubble level makes p...

Page 12: ...ed For larger values switch to the m3 unit of measure by pressing the m ft button 10 Continuous Measurement see Fig The continuous measurement serves for the transfer of dimensions for example from co...

Page 13: ...ctor The best pos sible results are achieved only when the laser beam and the measured distance form an exact right angle Pythagorean theorem In the illustrated example the length C is to be determine...

Page 14: ...ue first In the display the symbol ap pears The counter at the right next to the symbol shows the numbering of the displayed values The measured values displayed can still be entered into memory by pr...

Page 15: ...F Wait until the allowable temperature range is reached ERROR Message and m in the Display The angle between the laser beam and the target is too acute Increase the angle between the laser beam and th...

Page 16: ...e Service Center In case of repair send in the unit in the protective bag 30 Recycle raw materials instead of disposing as waste The unit accessories and packaging should be sorted for environment fri...

Reviews: