Section 4: Software Commands
Page 4-22
NetClock/GTP Instruction Manual
4.14
REMOTE OUTPUT CONFIGURATION
The command
REM 1
reads or sets the configuration of the RS-485 Remote Output.
Remote Output configuration options include: baud rate, data format, UTC or local time
with or without DST corrections.
To view the current Remote Output configurations, issue the command
REM1
as shown
below:
Type:
REM1 <ent>
Default Response:
REMOTE PORT 1
BAUD RATE= 9600 FORMAT #= 00
TIME DIFF= +00:00 DST= 0
To change the Remote Output configuration, place the clock in
Set Mode
and issue
the
REM1
command as follows:
Type:
REM1 [BAUD] [FMT] [TD] [DST] <ent>
Where:
BAUD
= Baud Rate: 1200, 2400, 4800, 9600
FMT
= Data Format: 00, 01, 02, 03, 04, 90: Refer to Section
3.3 for a complete description of the data formats
available.
TD
= Time Difference from UTC , ±00:00...±12:00; Refer to
Figure 4-2, UTC Time Difference Map.
DST
= DST rule number, 0...6.
Where: 0 = No DST, always Standard Time
1 = North America
2 = United Kingdom
3 = Continental Europe
4 = China
5 = Australian 1
6 = Australian 2
Example:
Configure the Remote Output port for data format 1, 1200 baud, Mountain
time with DST corrections.
Type:
SM ON <ent>
Response:
SET MODE ON
Type:
REM1 1200 01 -07:00 1 <ent>
Response:
BAUD RATE = 1200 FORMAT # = 01
TIME DIFF = -07:00 HOURS DST = 1