1.
Navigate to
MANAGEMENT > OTHER: Disciplining
.
2.
The
Oscillator Management
screen will display. It consists of two panels:
The Oscillator Status Panel
This panel provides comprehensive information on the current status of VelaSync's tim-
ing state.
Oscillator Type
: Type of oscillator installed in the unit.
Disciplining State
: State of oscillator control and disciplining; indicates whether or
not the internal oscillator is currently being disciplined (steered to an input ref-
erence). The states are: "Warm up", "Calibration", "Tracking Setup", "Lock
State", "Freerun", and "Fault".
1PPS Phase Error
: A tracking measurement [scaled time, in ns, or ms] of the
internal 1PPSs' phase error with respect to the selected input reference. Long
holdover periods or an input reference with excessive jitter will cause the phase
error to be high. The oscillator disciplining control will gradually reduce the phase
error over time. Alternatively, restarting the tracking manually (see "Restart
Tracking" under
"Configuring the Oscillator" on page 153
), or automatically via a
pre-set Phase Error Limit, will quickly reduce the phase error.
10 MHz Frequency Error
: An internal estimated calculation (in Hertz) of the
internal oscillator's frequency error, based on the phase accuracy error at the
beginning and end of a frequency measurement window (the length of this win-
3.4 Managing the Oscillator
CHAPTER
3
•
VelaSync User's Manual Rev. 3
157
Summary of Contents for VelaSync 1225
Page 2: ......
Page 4: ...Blank page II VelaSync User s Manual...
Page 12: ...BLANK PAGE X VelaSync User s Manual TABLE OF CONTENTS...
Page 28: ...16 CHAPTER 1 VelaSync User s Manual Rev 3 1 7 The VelaSync Web UI...
Page 34: ...BLANK PAGE 1 9 Regulatory Compliance 22 CHAPTER 1 VelaSync User s Manual Rev 3...
Page 104: ...BLANK PAGE 2 11 Configuring PTP 92 CHAPTER 2 VelaSync User s Manual Rev 3...
Page 251: ...Server management System specifications VelaSync User s Manual 239 APPENDIX...
Page 267: ...VelaSync User s Manual 255 APPENDIX...