4.
Enter the required information in the fields provided.
SNMP
User Names
and passwords are independent of users that are con-
figured on the
Tools/Users
page.
User names are arbitrary. SNMP
User Names
should be between 1
and 31 characters in length.
The
User Name
must be the same on VelaSync and on the man-
agement station.
The
Auth Type
field provides a choice between MD5 and SHA.
The
Auth Password
must be between 8 and 32 characters in length.
The
Priv Type
field provides a choice between AES and DES.
The
Priv Passphrase
must be between 8 and 32 characters in length.
The
Permissions
field provides a choice between Read/Write and Read
Only.
5.
Click
Submit
. The created user will appear in the
SNMP V3
panel:
Editing and Deleting Users
To edit or delete a user you have created:
1.
Navigate to
MANAGEMENT > NETWORK: SNMP Setup
.
2.
Click the row of the
SNMP V3
panel that displays the community you wish to edit
or delete. The cursor will change from an arrow icon to a pointing finger to indic-
ate that the entry is clickable.
3.
The
SNMP V3 Settings
window will display:
64
CHAPTER
2
•
VelaSync User's Manual Rev. 3
2.9 Configuring Network Settings
Summary of Contents for VelaSync 1225
Page 2: ......
Page 4: ...Blank page II VelaSync User s Manual...
Page 12: ...BLANK PAGE X VelaSync User s Manual TABLE OF CONTENTS...
Page 28: ...16 CHAPTER 1 VelaSync User s Manual Rev 3 1 7 The VelaSync Web UI...
Page 34: ...BLANK PAGE 1 9 Regulatory Compliance 22 CHAPTER 1 VelaSync User s Manual Rev 3...
Page 104: ...BLANK PAGE 2 11 Configuring PTP 92 CHAPTER 2 VelaSync User s Manual Rev 3...
Page 251: ...Server management System specifications VelaSync User s Manual 239 APPENDIX...
Page 267: ...VelaSync User s Manual 255 APPENDIX...