3.
To remove the power supply module from the VelaSync unit, push the release
tab to the side, and then pull the module straight out.
Figure 4-1:
Power supply removal
4.
Replace the failed power supply module with a replacement unit.
Note:
Only use the approved type of power supply, for more
information, see
"Maintenance and Service" on page 237
.
Simply push the new power supply module into the empty bay until you hear a
click.
5.
Plug the AC power cord back into the new power supply.
Note:
For additional information on the power supplies, see
https://www.supermicro.com/manuals/superserver/1U/MNL-1771.pdf
,
Chapter 2 on page 2-1.
4.3.2
Removing/Installing a Hard Disk Drive
Since the SATA Hard Disk Drives (HDDs) are hot-swappable, and they are RAID con-
figured, either of the two drives can be removed from the front of the VelaSync chassis,
without the need to open the chassis, or shut down VelaSync.
Caution:
Allow the hard disk drives to cool before touching.
164
CHAPTER
4
•
VelaSync User's Manual Rev. 3
4.3 Hardware Tasks