background image

Syntrack

 

 Synthesizer

3.   Set   the   desired   sound   with   the   controllers.   Should   you   wish   to   switch   over   the   volume 
envelope between Release and Decay, press the ENV 2 button.

4. To store the current controller settings, press the STORE button. The program is now stored. 
You can overwrite it as often as you wish, however.

1.5.5 Explanations on controllers / Technical data

Cut-off:

Cut-off frequency of the filter; 20..20'000 Hz

Resonance:

Also known as Q or regeneration. Feedback from the filter.

ENV Mod:

Modulation intensity of the filter envelope at cut-off frequency; positive of 
negative, max. approx. 10'000 Hz

Decay:

Decay time for the filter envelope; 0.01 .. 2.5 sec

Release/Decay:

Release / decay time of the volume envelope (ENV 2); 0.01 .. 3 sec. The 
function is switched over with button ENV 2.

Distortion:

Level of distortion: 0 .. max

Volume:

Volume level; 0 .. max

1.5.6 Using the external audio input

The input signal is mixed with the internal oscillator. If this is not desired, the wave number must 
be set to 99 (= no wave) via WAVESELECT. In the state of the system as delivered, it is also 
possible to select program 99, which contains wave number 99.

In order for the external signal to be audible, the Syntrack must receive a note command, so as 
to enable it to drive the VCA. This means that a connection is required at MIDI In, even if the 
Syntrack is only being used as a filter.

1.6 Initial start-up

Use  a  MIDI cable  to  connect  the  Syntrack´s  MINI In  socket  to  your  MIDI transmitting  device 
(master keyboard, sequencer, ...). If additional MIDI devices are to be connected down-line of the 
Syntrack, use an additional MIDI cable to connect the MIDI Thru socket of the Syntrack with the 
MIDI In socket of the next device.

If   you   wish   to   use   the   MIDI  Out   features   (real-time   recording   of   the   controller   movements, 
dump, ...) connect the MIDI Out socket of the Syntrack with the MIDI Input of your sequencer or 
your MIDI merger (device used to mix several MIDI data streams).

Connect the audio output to the audio input of your mixer, amplifier or similar.

Connect the power supply unit.

The display shows the number 01 (program). The MIDI channel is factory-set to 1. It must now be 
possible to play the Syntrack.

1.7 MIDI control

Each time a controller is moved, the Syntrack outputs the value as a controller output via MIDI 
Out. Program change commands and a Sysex dump are transmitted in the same way.

The  system is able  to receive and process the control  outputs  from the controllers  (in some 
instances MSB and LSB controllers), program change  commands, aftertouch, pitch-bend, MIDI 
clock, dump (Sysex) and system reset commands.

Page 5

Summary of Contents for SYNTRACK

Page 1: ...Owner s Manual Bedienungsanleitung...

Page 2: ...rogramme 4 1 5 4 Creating a user programme 4 1 5 5 Explanations on controllers Technical data 5 1 5 6 Using the external audio input 5 1 6 Initial start up 5 1 7 MIDI control 5 1 7 1 Dump 6 1 8 Format...

Page 3: ...ual has been produced with the greatest of care Spectral Audio is nevertheless unable to accept any responsibility for errors Reproduction is permissible only subject to the manufacturer s consent 1 2...

Page 4: ...not wish to store changes you must switch the instrument off and then on again The Syntrack is always in Standard mode after being started in this manner A brief black out of the display when the STO...

Page 5: ...ove the controllers These light emitting diodes indicate that the controller below is not currently active i e it is currently being remoted either via the MIDI controller or by the program memory As...

Page 6: ...eceive a note command so as to enable it to drive the VCA This means that a connection is required at MIDI In even if the Syntrack is only being used as a filter 1 6 Initial start up Use a MIDI cable...

Page 7: ...ll then use the lower nibble 25 mod 16 9 as receiving channel For reseting back to factory settings the Syntrack has to receive original sysex data You may use our factory sysex data from our homepage...

Page 8: ...is not set correctly 3 The GATE indicator does work but there is no sound or very distorted sound You have probably connected a DC power adapter and not an AC alternating current Make sure you use an...

Page 9: ...ves to 200 insert a new EPROM To insert the second wave EPROM turn off the unit Open the cover and insert the new EPROM next to the existing one Be sure that the mark on the EPROM looks to the same di...

Page 10: ...leistungsstarken Cascade Filter Klang erweitert mit einem Wavetable Oszillator Der Wavetable Oszillator bietet im Gegensatz zu den sonst blichen Analogen Oszillatoren bedeutend mehr Klangm glichkeite...

Page 11: ...anderen W rmequelle Setzten Sie es keinen Temperaturen ber 50 Grad Celsius oder unter 10 Grad Celsius aus Die Betriebstemperatur muss min 10 Grad Celsius betragen Transportieren Sie das Ger t vorsicht...

Page 12: ...gespeichert Wird dies nicht gew nscht muss das Ger t aus und wieder eingeschaltet werden Danach befindet sich der Syntrack immer im Normalmode Das kurzzeitige Erl schen des Displays beim Dr cken der S...

Page 13: ...ung der Leuchtdioden oberhalb der Regler Diese Leuchtdioden signalisieren dass der darunterliegende Regler im Moment nicht g ltig ist d h entweder via MIDI Controller gesteuert oder vom Programmspeich...

Page 14: ...ht gew nscht ist muss die Wavenummer mit WAVESELECT auf 99 gebracht werden keine Welle Im Auslieferungszustand kann ebenso das Programm 99 angew hlt werden es enth lt die Wavenummer 99 Damit das exter...

Page 15: ...in den Speicher des Syntracks geschrieben werden ist hierbei Vorsicht geboten Es ist z B m glich durch abge nderte Daten den MIDI Kanal auf 25 einzustellen Das Ger t verwendet in diesem Fall das tiefe...

Page 16: ...udio Verbindung zum Mixer defekt VOLUME ist Null Mixer nicht korrekt eingestellt 3 GATE Indikator funktioniert aber es kommt kein Sound oder sehr verzerrt Wahrscheinlich verwenden sie ein DC Netzger t...

Page 17: ...EPROM einzusetzen schalten sie das Ger t aus ffnen den Deckel und setzen das zweite EPROM neben das existierende in den Sockel Stellen sie sicher dass die Orientierungsmarke in die gleicher Richtung z...

Page 18: ...x o x o o o o x o o o x x x o o o o o o o o o o o o o o o o Modulation LFO Cutoff Frequency Cutoff LSB Master Volume LFO Frequency Resonance ENV1 Modulation ENV1 Mod LSB Decay ENV1 Distortion Release...