SpectraLink Corporation 

T1 Remote Module Installation 

 

Link WTS – Link 3000 MCU 

UL Information 

 

 

 

This symbol on the nameplate means the product is listed by Underwriter’s 
Laboratories, Inc. It is designed and manufactured to meet rigid U.L. safety 
standards against X-radiation, fire, casualty, and electrical hazards. 

The following are statements required for UL certification, related to safety procedures 
that must be adhered to during installation. 

 
Follow these general precautions while installing telephone equipment: 

• 

Never install telephone wiring during a lightning storm. 

• 

Never install telephone jacks in wet locations unless the jack is specifically designed 
for wet locations. 

• 

Never touch uninsulated telephone wires or terminals unless the telephone line has 
been disconnected at the network interface. 

• 

Use caution when installing or modifying telephone lines. 

When installing Base Stations outside or in buildings other than the one containing the 
System Controller, take the following precaution: 

If wiring for a Base Station exits a building—whether to reach an outdoor Base Station 
location or to reach a Base Station in another building—the wiring must be protected at 
both ends by a Quick Clip Fuse from Illinois Tool Works, Linx Division, model number 
SCP-2X2. The Quick Clip Fuse replaces the bridging clips on the 66 blocks for all four 
connections to the non-internal Base Station. 

Part Number: 72-0059-06-E.doc 

Page 4 

Summary of Contents for 3000 MCU

Page 1: ...T1 Remote Module Installation Link Wireless Telephone System Link 3000 MCU Part Number 72 0059 06 Issue E ...

Page 2: ... time performance suitability for use or performance of products described herein shall be deemed to be a warranty by SpectraLink for any purpose or give rise to any liability of SpectraLink whatsoever In no event shall SpectraLink be liable for any incidental indirect special or consequential damages whatsoever including but not limited to lost profits arising out of or related to this document o...

Page 3: ...quired to correct the interference at his own expense Note concerning shielded cable SpectraLink recommends the use of shielded cable for all external signal connections in order to maintain FCC Part 15 emissions requirements Note concerning the Wireless Telephone and Base Stations This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device...

Page 4: ...tions unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines When installing Base Stations outside or in buildings other than the one containing the System Controller take the following precaution If wiring for a ...

Page 5: ...ximum REN for your calling area If your telephone equipment causes harm to the telephone network the telephone service may discontinue your service temporarily If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be informed of your right to file a complaint with the FCC Your telephone company may make changes in its fa...

Page 6: ...or alterations made by a user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly i...

Page 7: ...LOCAL SITE 14 4 INSTALL SYSTEM AT REMOTE SITE 17 4 1 Survey Site 17 4 2 Install Shelves 17 4 3 Connect Power to Shelves 18 4 4 Install Cards 18 4 5 Connect Cables to T1 Remote Module 19 4 6 Connect Multiple Remote Shelves 19 4 7 Connect Demarc Block RJ 21 Cables to Interface Modules 21 5 CONFIGURE REMOTE SYSTEM 22 5 1 Configure Remote Shelf 22 5 2 Master Clock Configuration 23 5 3 Test System 23 6...

Page 8: ...te location via T1 facilities 1 1 Contacting SpectraLink SpectraLink wants every customer to have a successful installation Please refer questions to our Customer Support Hotline at 800 775 5330 The Hotline is open Monday through Friday 7 00 AM to 6 00 PM Mountain Time 1 2 Icons Used in this Document This manual uses the following icons and conventions Caution Follow these instructions carefully t...

Page 9: ...le Interface Module Interface Module Interface Module Interface Module Interface Module Interface Module Shelf 4 Expansion Shelf T 1 T 1 T 1 T 1 CSU CSU CSU CSU CSU CSU CSU CSU 1 2 3 4 5 6 7 8 9 10 11 12 T1 Remote Module Shelf Controller Card 1 2 3 4 5 6 7 8 9 10 11 12 T1 Remote Module Shelf Controller Card Interface Module Interface Module Interface Module Interface Module Interface Module Interf...

Page 10: ...he local site to the Intershelf Junction Panel and T1 facilities 4 Install Expansion Shelf at remote site 5 Install T1 Remote Module Shelf Controller and Interface Modules at remote site Note that GPS timing may be required when remote and main shelves are within 600 800 feet of one another 6 Connect T1 Remote Module at the remote site to the Shelf Controller and T1 Facilities 7 Install any additi...

Page 11: ...sions from the phone system at the appropriate cross connect demarc block and label the block 2 1 Required Materials Provided by Customer Rack the shelves are designed to fit into a 19 inch mounting rack Each shelf measures 15 high by 19 wide by 9 deep and weighs approximately 35 pounds fully loaded See Prepare Location for Shelves in the Link WTS Link 3000 MCU Installation document Backboard spac...

Page 12: ...ossible at both the System Controller site and the Expansion Controller site s One or two T1 circuits are required per remote Link 3000 MCU Expansion Shelf One T1 circuit is required for the first five Interface Module cards in a Remote Expansion shelf Two T1 circuits are required for 6 or more Interface Module cards installed in the remote expansion shelf Note that 1 10 Interface Module cards may...

Page 13: ...sion Shelf This card is installed in Slot 2 T1 Remote Module CRC301 one card for the remote site and one card for the local site for EACH remote shelf Cables two 12 foot RJ 45 cables with each Expansion Shelf Controller CSC300 RJ 45 cable to connect multiple shelves one for each shelf Interface Modules the correct number and type of Interface Modules to connect the Wireless Telephones and the Base...

Page 14: ... or her wrist and attach the other end of the strap to ground Only handle the cards by their edges Do not touch connector contact areas do not lift cards by any of the components and do not lay cards down on their component sides When laying a card down place it component side up on top of the anti static bag in which it was shipped Connect Intershelf Junction Panel Connect two RJ 45 cables from t...

Page 15: ...AUX port A on the Intershelf Junction Panel Note this shelf must also be designated as the Master Clock in the system configuration Connect T1 Facilities Connect the RJ48C jack from the CSU port at the local end to the DS1 A and DS1 B ports on the T1 Remote Module Port A controls slots 3 7 on the remote module at the far end Port B controls slots 8 12 The following diagram shows the T1 Remote Modu...

Page 16: ...ASTER IN SYNC OUT A B SYSTEM CONTROLLER SC A SC B EXPANSION SHELF CONTROLLER DS1 A LOS LIKOK DS1 B LOS LIKOK RJ45 to Intershelf Junction Panel T1 connection Module 3 7 on remote T1 connection Module 8 12 on remote To AUX Port on Intershelf Junction Panel for Net Clocked T1 Part Number 72 0059 06 E doc Page 16 ...

Page 17: ...ecurely fastened to the wall and mounting screws partially inserted into the backboard See Link WTS Link 3000 MCU Installation for more information To attach the shelves to the wall 1 Remove all cards from the shelf Do not mount the shelf with cards installed Cards contain components that may be damaged by electrostatic discharge Before handling any of the cards attach the grounding strap included...

Page 18: ...nts and do not lay cards down on their component sides When laying a card down place it component side up on top of the anti static bag in which it was shipped Install T1 Remote Module 1 Slide the T1 Remote Module into Slot 1 of the Expansion Shelf until the card clicks into place Tighten the screws at the top and bottom of the card to secure it Install Expansion Shelf Controllers CSC300 2 Slide t...

Page 19: ...LOS LNKOK Fully Loaded Remote Expansion Shelf 4 5 Connect Cables to T1 Remote Module Connect T1 Remote Module to Expansion Shelf Controller 1 Using an RJ 45 cable connect the Expansion Shelf Controller Port SC A in the T1 Remote Module slot 1 to the SC A port on the Expansion Shelf Controller slot 2 2 Using an RJ 45 cable connect SC B in the T1 Remote Module to SC B in the Expansion Shelf Controll...

Page 20: ...1 2 3 4 5 CRC 301 TIMING MASTER IN SYNC OUT A B SYSTEM CONTROLLER SC A SC B EXPANSION SHELF CONTROLLER DS1 A LOS LIKOK DS1 B LOS LIKOK From sync Out if more than one remote shelf To sync In if more than one remote shelf RJ 45 to Expansion Shelf SC A and SC B T1 connection to local Module 3 7 T1 connection to local Module 8 12 Part Number 72 0059 06 E doc Page 20 ...

Page 21: ...1 Cables to Interface Modules Connect the male RJ 21 connector from the appropriate demarcation block to the designated RJ 21 connector A or B on each Interface Module Secure the cables using the keeper Dress the cables by wire wrapping the cable at the rear of the shelf Part Number 72 0059 06 E doc Page 21 ...

Page 22: ...the right arrow or mouse to display options Use the arrow keys to highlight an option and press Enter to select the highlighted option T1 A State select T1 On to turn on T1 A T1 B State select T1 On to turn on T1 B Far Sync Source Leave the default None or select External Port if the far sync source is an external port Far Cluster Master Leave the default None if there is only one Expansion Shelf ...

Page 23: ...onsole select F8 Configuration Display and Administration The following screen displays 2 Select Field 12 Master Clock Cabinet 3 Enter the shelf number of the Master Clock shelf 4 Select SAVE to save the information 5 3 Test System The system should now be tested to ensure that it is functioning correctly See Test System in the Link WTS Link 3000 MCU Installation manual for more information Part N...

Page 24: ...ect Dump Config to PCS CFG See the Operator s Console document for more information Give the system administrator a map of the system showing the final Base Station locations at local and remote sites Perform end user and administrative training Get a signature on the acceptance document This document confirms that the installation has been correctly carried out that the coverage area is correct a...

Page 25: ... Installation Forms This section contains the following forms Base Station Locations Extension Assignments Site Preparation Checklist Customer Acceptance Form Copy these forms as needed Be sure to maintain completed forms for future reference Part Number 72 0059 06 E doc Page 25 ...

Page 26: ... Base Station 6 6 Shelf Number ________ Interface Module ________ Base Station Location e g building floor detailed description Interface Module Circuit Base Station 1 1 Base Station 2 2 Base Station 3 3 Base Station 4 4 Base Station 5 5 Base Station 6 6 Shelf Number ________ Interface Module ________ Base Station Location e g building floor detailed description Interface Module Circuit Base Stati...

Page 27: ...f _______ Interface Module _______ Phone Ext Name Interface Module Circuit Comment Wireless Telephone Serial Phone 1 1 Phone 2 2 Phone 3 3 Phone 4 4 Phone 5 5 Phone 6 6 Phone 7 7 Phone 8 8 Phone 9 9 Phone 10 10 Phone 11 11 Phone 12 12 Phone 13 13 Phone 14 14 Phone 15 15 Phone 16 16 Part Number 72 0059 06 E doc Page 27 ...

Page 28: ... are terminated with RJ 45 crimp on plugs at the designated locations One or two cross connect block s are installed for every Interface Module and connected with a 25 pair Telco cable terminated with an RJ 21 male connector at the MCU location The Base Station cables are terminated at the appropriate cross connect blocks Analog or digital ports one per Wireless Telephone from the switch are termi...

Page 29: ...l Wireless Telephones 5 Hand off was verified on all Base Stations 6 Coverage was confirmed for the areas specified at time of facilities analysis 7 Software was installed on customer s PC 8 A facilities map of the areas of coverage was given to the customer 9 Training class was given on use of Wireless Telephones 10 Administrative training was given to at least one user The following additional p...

Page 30: ...1 Grounding Strap 14 Hotline 8 Icons 8 Interface Modules 14 Installing 19 Intershelf Junction Panel 15 JPI300 15 Master Clock 24 Network Clocked T1 16 Configuration 23 24 Power 19 Remote Installation Diagram 9 Remote Installation Steps 11 Remote Shelf Configuring 23 Remote Site Surveying 18 Required Materials 12 Shelves Installing 18 Site Certification 25 Site preparation 12 Site preparation check...