Radio Based Synchronization
You define the synchronization chain (sync. chain) of the Spectralink IP-DECT Base Station through
the web based Administration Page of the Spectralink IP-DECT/Virtual IP-DECT Server. Radio syn-
chronization can be done either
or
Note:
Automatic configuration of radio synchronization is only supported on systems running
firmware PCS 20B_ or newer.
Note:
If using zone based paging, RPN's must be assigned to the relevant zones before syn-
chronization chain is defined.
Manual Configuration of Radio Synchronization
1. Click
Administration
, click
Base Station
, and then click on the relevant base station.
2. On the
Base station configuration
page, enter the following data:
Field
Base Station - General
IP address (Read only)
Current IP address of the base station.
Description (Optional)
Enter a description.
It is recommended to use a description of the physical loc-
ation.
RPN
Radio Part Number of the base station.
Note
: If using zone based paging, assigning base sta-
tions and RPN's are essential, as the RPN decides
which zone the Spectralink IP-DECT Base Station will
be part of. For more information, see
ing Sites, Zones and Assigning Numbers to Base Sta-
tions" on page 163
.
If using radio based synchronization in connection with
zone based paging, RPN's must be assigned to the rel-
evant zones before defining synchronization chain.