14215700-IG, Edition 15.0
May 2020, Original document
385
Configuration - Security
Field
Setting
Security Configuration - Administrator Authentication
Current password
Enter the current password.
New username
Enter a new username.
Note
: Requires a reboot of the server.
New password (Optional)
Enter a new password.
New password again
(Optional)
Enter the new password again to confirm.
Strict password requirements
(Optional)
If enabling strict password requirements, the device can be con-
figured to enforce certain security rules and naming con-
ventions. For more information, see
Note
: Once enabled, this setting can only be disabled by a fact-
ory reset (
Configuration
>
Factory Reset
) that will remove all
configuration and user data.
Password expiration (Optional)
Select when you want the password to expire.
Possible values:
Never
,
30 days
or
90 days
.
Default value:
Never
Note
: Once enabled, this setting can only be disabled by a fact-
ory reset (
Configuration
>
Factory Reset
) that will remove all
configuration and user data.
Security Configuration - Data protection
Allow unencrypted HTTP
(Optional)
HTTPS is forced by default.
If enabled, HTTP support is supported instead of HTTPS.
Note
: Enabling unencrypted HTTP can cause passwords and
other sensitive data to be transmitted in clear text on the net-
work.
Enable legacy TLS (Optional)
If enabled, TLS versions 1.0 and 1.1, certificates signed with the
SHA-1 algorithm and CBC based ciphers are supported.
Note
: Enabling legacy TLS is required for security and inter-
operability with some older browsers and call handing platforms.
Allow remote logging
(Optional)
If enabled, remote logging is allowed.
Remote logging allows for Spectralink debug tools to extract
debug information from the unit.