Spectralink IP-DECT Server 6500 Installation and Configuration Guide
14215700 Version 3.0
April, 2014
11
The Spectralink IP-DECT Server 6500 supports up to 4096 registered handsets.
Auto Login and Handover
Auto login
refers to the ability to log on to more than one system, enabling you to use the same
handset on up to 15 different systems. If a handset is subscribed to two or more systems, you can
use Auto Login.
•
Auto Login is used if a handset is subscribed to two or more systems.
Handover
refers to the ability to move between the coverage areas of different radio units on the
same system while talking, without interruptions in the conversation.
Requirements for the Spectralink IP-DECT Server 6500
Solution
This section provides information about the environmental and electrical requirements and
software requirements for the Spectralink IP-DECT Server 6500 solution.
Spectralink IP-DECT Server 6500/Spectralink Media Resources
Environmental Requirements
The installation area must:
•
be clean, free of traffic and excess dust, dry, and well ventilated
•
be within the temperature ranges of 10°C and 40°C/50°F and 104°F
•
be between 20% and 80% non-condensing relative humidity
Note
The installation area must be of sufficient height from the floor to prevent water damage. 1U
rack space in a 19" cabinet or respective space on the wall when mounting the KWS 6500 in