Shelf
Shelves are designed for 19 inch rack or wall mounting. Each shelf has 12
universal card slots. The first two slots are reserved for controller cards, the
remaining ten slots are for Interface Modules. Wiring to each card is on the front
panel. Power is -48V DC through the back or side panel.
System Controller (CSC or CSO301, 306, and 320)
Each system requires one system controller card, which occupies two slots (slot 1
and 2) in the main shelf. The system controller supports call routing within the
entire system and to external ports. Each model number of System Controller
(301, 306, and 320) supports a different number of expansion shelves. The CSO
model System Controller supports Open Application Interface (OAI) enabled
expansion shelves.
Two RS-232 serial ports are provided on the system controller. Serial ports can be
used for multiple purposes, including local administration, remote administration
and diagnostics (via modem), OAI applications and call detail recording. One
standard 10-base T Ethernet port is also provided (for future use).
Expansion Shelf (CSC300, CSO300)
An Expansion Shelf Controller (CSC-300) resides in slot 2 of each expansion
shelf. The Expansion Shelf Controller manages intra-shelf traffic and
communicates with the system controller. The CSO300 Expansion Shelf
Controller supports an OAI enabled expansion shelf.
Part Numbers with a CSO prefix have the same functionality and
capacity as the corresponding CSC Part Numbers and also support
the Open Application Interface(OAI)
Interface Modules (CPA, CPU, CPM, CPP, CPF316)
Telephone line and Base Station connections are made to the Interface Module.
Each card provides 16 line (Wireless Telephone) interfaces and 6 Base Station
interfaces. Interface Modules are installed in slots 3 through 12 on a shelf.
Interface modules include: Analog (CPA316), Universal (CPU316), Mitel
interface (CPM316), four-wire digital (CPF316), and Panasonic (CPP316). The
Interface Module type is defined via the Operator’s Console and software when
the card is installed. Interface Modules of different interface types can be mixed
within a shelf.
Interface Modules are “hot swappable”; they can be removed and replaced
without affecting service on the rest of the system.
Intershelf Junction Panel (JPI300)
The Intershelf Junction Panel (JPI300) connects Expansion Shelf Controllers on
expansion shelves to the system controller, creating a completed communication
channel between network elements. The Intershelf Junction Panel physically
Part Number: 72-0059-01-Ha.doc