REPLACEMENT PARTS:

Part Number

Part

Description

CF-IN-10-6JG

10" inline post carbon filter

Polishes water and removes any taste

V-ASO -4JG

ASO Valve

Completely shuts off Product water and Waste water

V-CK-IL-1LB -4JG

Check Valve

Used in conjunction with the ASO Valve.

OPTIONAL PARTS:

Part Number

Description

PPRFK-DI

Permeate Pump Retrofit Kit used for RO/DI systems

BPLF-PS -115

Booster pump kit for use with up to 25-60 GPD system

BPHF-PS-115

Booster pump kit for use with over 60 GPD systems

V-PREG -0 -125-4GJ

Pressure reducing valve (pressure regulator)

TANK-SN03-4 

3 Gallon Pressurized Storage Tank 

TANK-SN04-4

4 Gallon Pressurized storage Tank

Summary of Contents for Drinking Water Kit

Page 1: ...ly before proceeding with installation Failure to follow any attached instructions or operating parameter may lead to the product s failure and possible damage to property SpectraPure Inc assumes no responsibility for water damage due to leaks It is the user s responsibility to determine that the system is leak free v4 2013 12 03 ...

Page 2: ...he Drinking Water Kit 4 Configuring a Legacy non MF AF System For the Drinking Water Kit 5 Ice Maker Hookup optional 5 Diagram of RO DI System With Drinking Water Kit Installed 6 Preparation 7 Feed Supply Valve Installation 8 Faucet Installation 9 Drain Saddle Installation 10 Installing Pressurized Storage Tank and Mounting System 11 Startup Procedures 11 Maintenance Sanitizing the RO DI System wi...

Page 3: ... THEN A PRESSURE REGULATOR MAY BE REQUIRED CONTENTS OF DRINKING WATER KIT DRINKING WATER ADD ON KIT 1 Pressurized Storage Tank 1 Inline Carbon Block w Push Fittings 1 Faucet with parts bag 1 Feed Water Adapter 1 Galvanized Flange 1 Drain Saddle 1 Rubber Washer 1 Ball Valve Right Angle for the top of tank 1 Flat Metal Washer with U Cutout 1 Automatic Shut off Valve ASO 1 Plastic Spacer with Cutout ...

Page 4: ...supplied in the kit 4 Cut the blue tube still connected to the membrane housing down so there is only 1 inch of tubing exposed Connect a 1 4 Check Valve to this blue tube with the arrow pointing away from the blue tube 5 Cut a piece of blue tube down to 2 inches Connect one end to the the remaining free end of the Check Valve and the other end to the ASO Valve Note the arrow should be pointed towa...

Page 5: ...odels without automatic or manual flush 1 Locate the Black Tube between the Carbon Filter and the Membrane 2 Cut the Black Tube in two 3 Insert the cut end from the Carbon Filter into the IN Port of the ASO Valve 4 Insert the cut end from the RO Membrane Housing into the OUT Port of the ASO Valve 5 Locate the Blue Tube product water that leaves the RO Membrane Housing 6 Cut the Blue Tube 2 from th...

Page 6: ...nc 480 894 5437 Call us toll free 1 800 685 2783 2167 East Fifth St Tempe Arizona 85281 6 RO DI SYSTEM WITH DRINKING WATER KIT INSTALLED FOR RO ONLY SYSTEMS CONNECT ASO PORT A TO TANK TEE B CHECK VALVE AND TEE NOT REQUIRED A B ...

Page 7: ...tial damage resulting from the installation of the faucet STEP 1 Determine a desired location for the faucet on your sink and place a piece of masking tape on the location where the hole is to be drilled Mark the center of the hole on the tape STEP 2 Use a variable speed drill on the slowest speed Drill a 1 8 Pilot hole through both porcelain and metal casing of sink at the center of the desired l...

Page 8: ...Tubing into the Compression Nut with the threads towards the end of the tube c Slip the Conical Compression Sleeve onto the Black Tube with the long slope pointing toward the end of the tube d Place the Insert into the end of the Black Tubing Make sure you push the insert in all the way e Tighten Compression Nut back on the Valve body STEP 5 When installation of the valve is complete check for lea...

Page 9: ...eeve 4 Place the Insert into the end of the Blue Tubing Make sure you push the insert in all the way Screw the Compression Nut onto the threaded shaft 5 Securely tighten both hex nut and Compression Nut 6 DO NOT CUT EXCESS TUBING AT THIS POINT YOU WILL NEED THE TUBING TO INSTALL THE TANK TIP When connecting the tubes to the hose barbs try using HOT water to soften the plastic tubes When connecting...

Page 10: ... a small punch and indent a start position to prevent the drill bit from wandering Drill a 3 8 hole in the drain pipe through the mark on one side only do not drill through both sides of the drain pipe 4 Clean any loose shavings from around the hole 5 Refer to Figure 5 showing the drain saddle assembly sequence Press nuts in back half of drain saddle assembly 6 Align the front half of the drain sa...

Page 11: ...ps screwdriver Measure the distance between the key hole slots on the back of the bracket and install screws Leave enough space and tubing so that you can pull the system out for maintenance STARTUP PROCEDURES 1 Slowly turn the cold water supply to full flow Check for leaks 2 Turn the valve on the storage tank to the OFF position and open the faucet 3 Watch the clear housings fill with water When ...

Page 12: ...MMEDIATELY close the faucet as soon as the bleach solution appears This will sterilize the faucet and the line going to the faucet 11 Let the system sit for 2 hours 12 Open the dispenser faucet to drain bleach solution from the pressure tank as completely as possible and then close the faucet 13 Open the feed supply valve fully 14 Allow the tank to fill until pressure gauge reaches 40 psi Then ope...

Page 13: ...rize bladder to 7 psi when empty h too much pressure in bladder tank viii Repressure bladder to 7 psi when empty i ruptured bladder ix Replace tank j back pressure exerted by the pressurized bladder tank causes a reduction in production rate x Use of permeate pump retrofit kit PPRFK DI eliminates the back pressure 2 ZERO PRODUCTION RATE a missing flow restrictor i Put flow restrictor in the yellow...

Page 14: ...st carbon filter iii Replace post carbon filter 5 MILKY COLORED WATER a Air in system i Air in the system is a normal occurrence with intial startup of the RO DI system This milky appearance will disappear during normal use within 1 2 weeks If condition recurs after filter changes drain tank 1 to 2 times 6 REJECT YELLOW LINE NEVER STOPS FLOWING WATER a Faulty 1 lb check valve i Replace it b Faulty...

Page 15: ...stallation including but not limited to failure by installer to over or under tighten fittings housings and or push style fittings or improper installation of push style fittings To obtain service under this warranty the defective system or components must be returned to SpectraPure with proof of purchase installation date failure date and supporting installation data Any defective product to be r...

Page 16: ...s off Product water and Waste water V CK IL 1LB 4JG Check Valve Used in conjunction with the ASO Valve OPTIONAL PARTS Part Number Description PPRFK DI Permeate Pump Retrofit Kit used for RO DI systems BPLF PS 115 Booster pump kit for use with up to 25 60 GPD system BPHF PS 115 Booster pump kit for use with over 60 GPD systems V PREG 0 125 4GJ Pressure reducing valve pressure regulator TANK SN03 4 ...