SYSTEM INSTALLATION & INITIALIZATION:
1. Most of the components of this system are plastic and are subject to damage by
ultraviolet light from the sun and other sources such as metal halide lighting.
2. Avoid installing this unit in an area where it may be subjected to bright light
or direct sunlight, as algae is more likely to thrive inside the clear filter housings
when exposed to bright light. The unit must be kept out of areas that are
subject to freezing temperatures.
3. High temperatures greater than 113° F (45° C) must be avoided. If the unit is
used outside, avoid putting the system in direct sunlight or connecting it to a
garden hose that may be exposed to sunlight.
4. Attach the black tap water tubing to the left side of the Sediment Filter Housing
(See page 8.).
5. Attach the yellow drain line to the “Y”- connector at the rear of the system. This
“Y” -connector already has a yellow and green tube attached to it. (See Page 9.)
6. Attach the blue product line to the rear port (after the “tee”) of the right-hand
DI housing.
7. Attach the garden hose adapter
(connected to the black tubing)
to your
cold water source. Never run hot water (greater than 113° F/45° C) through
the system.
8. Remove the two DI filter cartridges from the two right-hand filter housings.
Reconnect the two housings to their threaded caps. Hand tighten.
9. A provided ball valve can be located at a convenient place on the black tap
water line. Cut the black tubing in two and reconnect the two cut ends with
the ball valve.
10. Place the
yellow concentrate (waste) tubing
and the
blue purified (product)
water tubing
temporarily into a drain. Do not restrict flow from these lines.
11. Let both tubings run water down the drain for one hour.
12. Reinstall the two DI cartridges into the DI housings. Hand tighten.
13. There are two groups of red, white, and blue sensor wires. At the end of
the wires, you will find a white connector. Insert the connector into the
receptacle on the top of each TDS monitor. You can then use the Velcro on
the back to mount the meters to the front of the system or close by on a wall
for easier viewing.
Attach Blue Product
tubing here