8. Place the black housing O-ring on the housing rim and carefully screw
the lid back on to the base.
9.
Housing O -Ring
Reconnect the black tubing to the membrane feed push fitting.
NOTE: If you have a dual-membrane system, perform steps 2 thru 9
on the second membrane now.
*
If the new replacement membrane is rated differently in gallons per
day than the original membrane, you will need to remove the old
flow restrictor, replace it with the correctly matched one and follow
this procedure for adjustment:
1. Disconnect the yellow concentrate tubing (page 11) from the membrane
housing. Remove and discard the flow restrictor (Fig. E).
2. Reconnect yellow concentrate tubing back to membrane housing
and run water through system for at least 2 gallons. (This step will
flush out membrane preservatives.)
3. Insert the new flow restrictor and follow procedure on page 8-9 for
measuring waste to product water ratio.
4. Check for leaks. Allow at least 2 gallons of water to run through the
system before using water.
*
I
f the replacement membrane is rated identical in gallons per day to
the original membrane:
1. Disconnect the yellow concentrate tubing (page 11) from the membrane
housing. Remove flow restrictor and set aside.
2. Reconnect yellow concentrate tubing back to membrane housing
and run water through system for at least 2 gallons. (This step will
flush out membrane preservatives.)
3. Reinsert flow restrictor and check for leaks. Allow at least 2 gallons of
water to run through the system before using water.