RO MEMBRANE REPLACEMENT
1. Turn off the water supply to the RO system. Place the system
where the membrane housing is easily accessible.
2. Remove the black tubing from the membrane feed push-fitting
by depressing the collar on the fitting with your thumb and pulling
the tubing from the push-fitting (Page 10).
3. Lift the membrane housing from the retention clips.
4. Unscrew the membrane housing lid. This may require two people.
5. Use a pair of pliers to grasp the membrane stem and pull the
membrane from the housing (Fig. F).
6. Remove the black housing O-ring (Fig. F). Wash the empty housing
with soapy water. Rinse thoroughly with hot, clean water.
7. Insert new membrane into the housing, with the double
O-ring end first (Fig. G). The tube must fit into the recess at the
bottom of the membrane housing. When the membrane is aligned
with the hole, firmly push the membrane into the hole until it
bottoms
out.
Fig. F: Removing the Membrane Element
Fig. G: Inserting the New Membrane Element
black
membrane
brine seal
black
membrane
housing O-
ring
membrane
product
water tube
double O-ring
end of membrane
product water
stem tube