17
SpectraPure
®
Housing O-Ring
8. Place the black housing O-ring on the housing rim and carefully
screw the lid back on to the base.
9. Reconnect the black tubing to the membrane feed push-fitting.
Note: If you have a dual-membrane system, perform steps 2 thru 9 on
the second membrane now.
* If the new replacement membrane is different in gallons
per day than the original membrane, you will need to remove the
old flow restrictor, replace it with the correctly matched one and
follow this procedure for adjustment:
1. Disconnect the yellow concentrate tubing (page 10) from the
membrane housing. Remove and discard the flow restrictor
(Fig.
E).
2. Reconnect yellow concentrate tubing back to the membrane
housing and run water through system for at least 2 gallons.
(This step will flush out membrane preservatives.)
3. Disconnect the yellow tubing again and insert the new flow
restrictor. Follow procedure on page 8-9 for measuring waste
to product water ratio.
4. Check for leaks.
* If the replacement membrane is identical in gallons per day to the
original membrane:
1. Disconnect the yellow concentrate tubing (page 10) from the
membrane housing. Remove flow restrictor and set aside.
2. Reconnect yellow concentrate tubing back to membrane
housing and run water through system for at least 2 gallons.
(This step will flush out membrane preservatives.)
3. Re-insert flow restrictor and check for leaks.