INSTALLATION

No part of this publication may be reproduced, stored in a retrieval system, or transmitted 
in any form or by any means, electronic, mechanical, photocopying, recording or otherwise 
without the prior written permission of SpectraPure Inc.

COPYRIGHT 2002-2005© BY SPECTRAPURE INC

ALL RIGHTS RESERVED

TABLE OF CONTENTS

Table of Contents and Term

................................................................................................2-3

Warranty Information

...............................................................................................................4

Systems Information

What is Reverse Osmosis...................................................................................................5
System Specifications..........................................................................................................6
System Description..........................................................................................................7-8

Installation

Installing Water Purity Monitor...................................................................................8-9
System Initialization..........................................................................................................10
Checking Waste to Product Water Ratio.............................................................11-12
Flow Restrictor Removal, Adjustment and Replacement...............................13-14

Filter Diagnostics

Sediment Filter Diagnostic.............................................................................................15
Carbon Filter Diagnostic.................................................................................................15
Deionization Cartridge Diagnostic........................................................................16-17
RO Membrane Diagnostic.......................................................................................18-20

Troubleshooting Guide

Troubleshooting Guide for the System......................................................................21
Troubleshooting Purity Monitor...................................................................................22
Troubleshooting the RO Membrane....................................................................23-26
Mounting Locations.........................................................................................................27

Replacement & Optional Parts

............................................................................................28

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: spectra@spectrapure.com Visit us on the web www.spectrapure.com

27

SpectraPure

®

CHOOSING A MOUNTING LOCATIONS

When considering a location for the installation of the 
RO System, consider the following factors:

Light Sources

1.    Most of the components of this system are plastic and 
 

 are subject to damage by ultraviolet light from the sun 

 

 and other sources such as metal halide  lighting.

2.   Algae is more likely to thrive inside the clear filter housings 
 

 when exposed to bright light.

3.   Avoid installing this unit in bright light or direct sunlight.

Temperature Extremes

1.   The unit must be kept out of areas that are subject to freezing
  

temperatures.

2.   High temperatures greater than 100° F (38° C) must be 
 

 avoided. If the unit is used outside, avoid putting the 

 

 system in direct sunlight or connecting it to a

 

 garden hose that may be exposed to sunlight.

Summary of Contents for SpectraPlus 2000

Page 1: ...trictor for 180 gpd 680 lpd System DI SFCI 10 SilicaFree Color Change DI Cartridge DI AR CI 10 Chloramine Removal Cartridge GHA 4 1 4 6 35 mm Garden Hose Adapter XWR UNIV Filter Wrench Optional Accessories Model Optional Part FAU SMP Quick Connect Faucet Coupler TS C61 Micro Siemens Conductivity Tester 0 1999 uS cm TS T71 Total Disolved Solids Tester 0 1999 ppm TDS TK CL 25 Total Chlorine Test Kit...

Page 2: ...18 20 Troubleshooting Guide Troubleshooting Guide for the System 21 Troubleshooting Purity Monitor 22 Troubleshooting the RO Membrane 23 26 Mounting Locations 27 Replacement Optional Parts 28 SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 27 SpectraPure CHOOSING A MOUNTING LOCATIONS When considering a location...

Page 3: ... specified 3 This warranty is in lieu of all other warranties expressed or implied including warranties of fitness for a particular purpose 4 We do not authorize any person or representative to assume for us any other oblligation on the sale of our equipment This is the exclusive remedy and liability for consequential damages under any and all warranties which are excluded to the extent exclusion ...

Page 4: ...quipment and all returned goods must also have adequate insurance coverage and a tracking number SpectraPure will not pay for loss or damage caused directly or indirectly by the presence growth proliferation spread or any activity of fungus wet or dry rot or bacteria Such loss or damage is excluded regardless of any other cause or event that contributes concurrently or in any sequence to the loss ...

Page 5: ...ost salts and other impurities are rejected and automatically rinsed from the membrane down the drain Figure 1 Figure 3 WHAT IS REVERSE OSMOSIS Osmosis is a process in nature that allows fluid of a lower concentration to pass through a semi permeable membrane into a fluid of a higher concentration See Figure 1 Because of the difference in salt concentration pure water flows through the membrane as...

Page 6: ...30 more than 49 GPD use BPHF MO 115 230 Operating pressure greater than 80 psi will require a pressure reducing valve SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 23 SpectraPure TESTING THE QUALITY OF THE MEMBRANE Membrane Output Calculation Membranes produce the rated gallons per day GPD at 60 psi 4 1 bars ...

Page 7: ...lter This filter is required to remove excess turbidity particulate matter that may cause the carbon block filter to plug 2 The second stage of filtration is a 0 5 micron carbon block pre filter This filter removes organics and chlorine from the feed water that can damage the membrane 3 The third filtration stage of the system is a high rejection thin film composite TFC reverse osmosis membrane It...

Page 8: ...STEMS 1 Low production rate a plugged pre filters i Replace pre filters b low water temperature ii Heat feed water OR use higher GPD membrane c low line pressure iii Use booster pump OR use higher GPD membrane d high TDS content iv Use booster pump OR use higher GPD membrane e fouled membrane v Clean or replace membrane to restore flux f plugged flow restrictor vi Replace flow restrictor membrane ...

Page 9: ... the web www spectrapure com 9 SpectraPure Fig C Purity Monitor Without Cover Switch Number 1 2 3 4 5 6 7 8 Setting in uS 100 50 20 10 5 2 1 0 5 Setting in ppm 67 33 13 6 7 3 3 1 3 0 67 0 33 Fig B Purity Monitor Switches If settings are changed for any reason such as testing the quality of the RO membrane They should be returned to the original 7 setting after completion of the test Switch 7 Shown...

Page 10: ... is the user s responsibility to determine that the system is leak free SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 19 SpectraPure RO MEMBRANE REPLACEMENT 1 Turn off the water supply to the RO system Place the system where the membrane housing is easily accessible 2 Remove the black tubing from the membrane...

Page 11: ...eceive the most accurate mea SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 11 SpectraPure CHECKING THE CONCENTRATE TO PURIFIED WATER RATIO This procedure will assure you of maximum life and reliability of your SpectraPure System Failure to perform this procedure can permanently damage the membrane and will vo...

Page 12: ...MENT Right most housing The last stage is a dual layer cation anion cartridge or in some cases a mixed bed DI The condition of this cartridge should be judged by observ ing either a RED or GREEN light indication from the monitor Please note that the probe is located after housing 4 Thus the monitor indicates the condition of the final DI stage cartridge only Turn the on the system and allow water ...

Page 13: ...oll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 13 SpectraPure FLOW RESTRICTOR REMOVAL ADJUSTMENT AND REPLACEMENT 1 Locate the yellow concentrate tubing Fig E Remove the tubing from its push fitting at the membrane as follows a Firmly depress and hold the push fitting collar down with your thumbnail b While the push fitting collar is depressed pull th...

Page 14: ...he sediment and carbon pre filters must be changed when a 15 20 drop in pressure is observed OR at least 6 month intervals If your water contains a great deal of sediment or chlorine the pre filters may require more frequent changes to maintain adequate production rate and extended membrane life Sediment Pre Filter Replacement Materials Required 0 5 micron MicroTec Sediment Filter SF MT 0 5 10 Fil...