The AccuMAX XR-1000 digital readout unit with the XS-365 UV sensor or
the Spectroline DM-365XA digital readout unit can also be used for
accurate UV-A measurement.
For more information about these units, please contact the Customer
Service Department at Spectronics Corporation. In the U.S. and Canada,
call toll-free 1-800-274-8888.
ELECTRICAL AND TECHNICAL SPECIFICATIONS
MODEL
TYPE
VOLTS
Hz
AMPS
FUSE
UV-400A
Concentrated Beam
120V
60
4.12
5A (1)
UV-400B
Broad Beam
120V
60
4.12
5A (1)
UV-400A/FE Concentrated Beam
230V
50
5
6.3A (2
)
UV-400B/FE Broad Beam
230V
50
5
6.3A (2
)
Each unit uses a 400-watt metal halide bulb (supplied), P/N BLE-400
Wavelength 320–400nm
Dimensions (W x D x H), 15.25 x 12.25 x 12 in (38.7 x 31.1 x 30.5 cm)
Weight 29.5 lb (13.4 kg)
NOTES
120V units require one fuse, ABC series, FAST, ceramic, 250V, P/N EC-0222-05
230V units require two fuses, 6.3A, TD (time delayed), 5x20mm, 250V,
P/N 125666
Models /FB (Britain), /FA (Australia) and /J (Japan) are available upon request.
Each unit is fitted with the proper cord set and plug for its country of destination.
ENVIRONMENTAL CONDITIONS
The SuperFlood™ UV-400 Series UV lamps are designed to be safe
under the following conditions:
• Indoor use;
• Altitude up to 2,000 m (6,562 ft.);
• Temperature 5°C to 40°C (41°F to 104°F);
• Maximum relative humidity 80% for temperatures up to 31°C (88°F),
decreasing linearly to 50% relative humidity at 40°C (104°F);
• Mains supply voltage fluctuations not to exceed ±10% of the
nominal voltage;
• Installation Category II;
• Pollution Degree 2.