background image

8

WARRANTY

The warranty policy for the UV-400 SuperFlood Series UV lamps is provided 

on the Certif 

icate of Limited Warranty enclosed separately with 

 

each unit.

NOTE

: For assistance of any kind, contact the Customer Service 

Department at Spectronics Corporation. Give full details of the 

 

difficulty and include the model and serial numbers of the unit and the 

date of purchase.

If return of the unit to the factory is deemed necessary, shipping 

 

instructions will be provided. If an estimate of charges for nonwarranty 

work or other service work is required, a quote will be furnished upon 

evaluation of the unit. Out-of-warranty service work will not be performed 

without customer approval.
Use only replacement parts supplied by Spectronics Corporation.  Use of 

any other parts may damage the unit and void the warranty.

SHIPPING

Carefully pack the unit in its original shipping container and packing  

materials and ship it prepaid to the factory. Insure it for full value.

LAMP CONTAINS MERCURY

Manage in Accord with Disposal Laws

See: www.lamprecycle.org

REPLACEMENT PARTS AND ACCESSORIES

Description 

Part No.

400-Watt Metal Halide Bulb   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BLE-400
UV-A Filter    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2F110
UV-B Blocking Filter   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2F400B 
Air Filter   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125037
Spring-Loaded Socket (UV-400, UV-400B) . . . . . . . . . . . . . . . . . . . . EC-0416
Igniter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  EC-0434
Lamp Holder (UV-400A)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126055
Ballast (120V)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100028 
Ballast (230V)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102501
Latch, Adjustable Grip 
    Left   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MC-0483
    Right  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MC-0484
Spectacles, UV-Absorbing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UVS-30
Goggles, UV-Absorbing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UVG-50
Face Shield, UV-Absorbing    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UVF-80

Summary of Contents for Spectroline SuperFlood UV-400 Series

Page 1: ...OPERATOR S MANUAL SuperFlood UV 400 Series UV Lamps AM07008 9 Printed in U S A August 2012 ...

Page 2: ... protection provided by the equipment may be impaired The lamp is completely safe when used as directed see MOUNTING INSTRUCTIONS FOR SAFE OPERATION We recommend using Spectroline UV absorbing protective eye and face wear See REPLACEMENT PARTS AND ACCESSORIES for model numbers This eye and face wear also improves contrast between the fluorescent area and the background and eliminates blue haze int...

Page 3: ... avoids the restarting delay 6 Restarting of the lamp will not occur immediately as the metal halide vapor within the bulb must first cool off The restarting delay can range up to five minutes or longer 7 Any interruption in the power supply such as an excessive voltage drop will extinguish the arc Restarting will again be delayed while the metal halide vapor cools off and full voltage is again av...

Page 4: ...late closest to the back of the unit see Diagram 2 below 2 Attach two pieces of chain link not supplied to the eyelet bolts NOTE Depending on the ceiling size and application select the appropriate chain link size Chain link rated for 100 pounds is recommended 3 The lamp will now hang at a 45 angle Diagram 2 4 UV Beam Area Chains ...

Page 5: ... MAINTENANCE The aluminum lamp housing is designed for protection of the internal parts Using a soft cloth immediately clean spills from the housing with water and a mild detergent and wipe dry Do not allow any liquids to touch the filter when it is hot or to penetrate into the unit s electrical components Periodically clean the filter with a glass cleaner and a soft cloth FILTER REPLACEMENT NOTE ...

Page 6: ...re failure If you should inadvertently touch the envelope use the alcohol treated tissue provided or other nonflaking tissue dipped in alcohol to clean the surface The bulb must be perfectly clean before it is installed in the lamp 4 Note that the bulb sits between two spring loaded metal tips that are part of a ceramic assembly To remove or replace the bulb push the bulb toward one of the spring ...

Page 7: ...h 320 400nm Dimensions W x D x H 15 25 x 12 25 x 12 in 38 7 x 31 1 x 30 5 cm Weight 29 5 lb 13 4 kg NOTES 120V units require one fuse ABC series FAST ceramic 250V P N EC 0222 05 230V units require two fuses 6 3A TD time delayed 5x20mm 250V P N 125666 Models FB Britain FA Australia and J Japan are available upon request Each unit is fitted with the proper cord set and plug for its country of destin...

Page 8: ...ork will not be performed without customer approval Use only replacement parts supplied by Spectronics Corporation Use of any other parts may damage the unit and void the warranty SHIPPING Carefully pack the unit in its original shipping container and packing materials and ship it prepaid to the factory Insure it for full value LAMP CONTAINS MERCURY Manage in Accord with Disposal Laws See www lamp...

Reviews: