background image

WatchDog model 200, 225, 400, 425, and 450 loggers have 
external channels (ports) for external sensor input.  The following 
table lists the available optional sensors.  Most sensors include a 6-
foot cable with pin-type connector.  Items 3667-20 and 6450WD20 
have 20 foot cables. 

Item # 

Description 

Measurement 
Range  

Accuracy 

3665R 

Tipping Bucket Rain 
collector 

N/A 

±2% 

3666 

Leaf Wetness Sensor 

0(Dry) - 15(Wet) 

N/A 

3667 
3667-20 

External (Soil) 
Temperature Sensor 

-30° to 100°C 
-22° to 212° F 

±0.6°C 
±1°F 

3670 

Silicon Pyranometer 

1-1250 W/m

2

 

±5% 

3668 

Quantum Light Sensor 

0-2500 umol  m

-2

s

-1 

±5% 

3669 
3669LT 

Soil Moisture  
Transducer 

0-100 kPa 

±2% 

6450WD  
6450WD20 

Watermark Soil Moisture 
Sensor 

0 - 200 cbars 

N/A 

6451 

Irrigation Sensor 

Switches at 5 psi 

±1 psi 

3673 
3674 

Input Cable for user-
supplied  
sensor 

0-2.5V  
4-20mA 

N/A 

External Sensors 

To connect the external sensor to the logger, plug the data cable 
into the logger port that has been programmed for that particular 
sensor.  If the sensor is not connected,  a “- - -” will appear on the 
LCD display for the respective logger port until the sensor is 
connected.  
 

Port A is the only channel that will record rainfall data 
 

Program each channel (port) to a specific sensor through the 
SpecWare launch screen.  Refer to the 

SpecWare Software 

User’s Guide 

for more detailed instructions on launching and 

sensor configuration. 

Summary of Contents for WatchDog 200

Page 1: ...Operation Manual WatchDog Data Loggers Model s 200 225 250 400 425 450 Technologies Inc Spectrum...

Page 2: ...440 between 7 30 am and 5 30 p m CST FAX at 815 436 4460 or E Mail at info specmeters com www specmeters com Spectrum Technologies Inc 12360 S Industrial Dr East Plainfield IL 60585 CONTENTS General O...

Page 3: ...into the logger port and configure the logger to the corresponding sensor through the software Download the accumulated data at your convenience using the powerful SpecWare software SpecWare will pre...

Page 4: ...rements 3 500 per channel 1 250 Temp RH 4 to 158 F 20 to 70 C 20 100 RH 5 to 50 C 1 F 0 6 C 3 RH 7 000 measurement 3 500 per channel None 400 None N A N A 15 000 measurements 3 750 per channel 4 425 T...

Page 5: ...5 3669 3669LT Soil Moisture Transducer 0 100 kPa 2 6450WD 6450WD20 Watermark Soil Moisture Sensor 0 200 cbars N A 6451 Irrigation Sensor Switches at 5 psi 1 psi 3673 3674 Input Cable for user supplie...

Page 6: ...to the illustration as an example of how to install your mini weather station For outdoor and greenhouse use the WatchDog logger must be placed in a mini radiation shield to protect it from solar radi...

Page 7: ...WatchDog connected to the computer is during the launching and downloading of the data logger After the logger has been launched and or downloaded disconnect the logger and place it in the environment...

Page 8: ...SpecWare software to launch the logger to record specified parameters at chosen measurement intervals Interval choices offered are 1 5 10 15 30 60 and 120 minutes Use SpecWare software to read out th...

Page 9: ...ternal sensors A complete cycle takes approximately 8 seconds for a model 200 series logger and 16 seconds for a model 400 series logger ex a model 225 with 2 channels would take 8 seconds to cycle or...

Page 10: ...Remove the back cover 3 Slide the battery out of the battery holder 4 Insert a new CR2032 battery positive side up 5 Replace WatchDog cover 6 Tighten back cover screw Confirm that the logger is activ...

Page 11: ...ot securely plugged into a channel port Q Why is logger displaying and or logging bogus or out of range readings A External sensors are not plugged into correct ports Trouble Shooting The WatchDog dat...

Page 12: ...Spectrum at your expense with the RGA number marked clearly on the outside of the package Spectrum is not responsible for any package that is returned without a valid RGA number or for the loss of the...

Reviews: