background image

23

Conduit Entries are M20 x 1.5 Use appropriate Adapter
With Nylon Washer or O-ring to keep ingress protection

D201-1-Q6055 REV 4 105607312018 D SERIES  

INSTALLATION MANUAL REV-1

INSTALLATION

CAUTION: 

Ensure the ethernet cable is disconnected from power  

source prior to wiring to the terminal block

Figure 3.

Figure 4.

Summary of Contents for D201 Q6055-E-BD Series

Page 1: ...SPECTRUM D201 1 Q6055 E BD Series D201 A Q6055 E BD D201 S Q6055 E BD Explosion Proof Network Camera Installation Manual D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 1 ...

Page 2: ...Thispageintentionallyleftblank 2 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 ...

Page 3: ...rk s and the rights of the trademark s owned by the company referred to herein Release Date 08 30 2018 Document Name D201 1 Q6055 E BD Copyright 2019 by Spectrum Camera Solutions LLC All rights reserved Revision Record Rev Description Date 0 Initial Release Aug 30 2018 1 Updated Oct 10 2018 2 EU July 15 2019 3 Format adjust Feb 5 2020 4 coc Feb 18 2020 D201 1 Q6055 REV 4 105607312018 D SERIES INST...

Page 4: ... exercising maximum possible legal action against all persons and or organizations involved Disclaimer Spectrum Camera Solutions LLC makes no representations or warranties with respect to the contents hereof Further Spectrum Camera Solutions LLC reserves the right to revise this publication and to make changes in the content hereof without obligation to notify any person or organization of such re...

Page 5: ...L REV 1 5 Page DESCRIPTION 6 MODEL MATRIX 7 LABELS 8 STANDARDS AND CERTIFICATIONS 9 DOCUMENT SYMBOLS 10 HOW TO USE THIS MANUAL 11 GENERAL SAFETY AND OPERATING INFORMATION 12 SPECIFICATIONS 15 UNBOXING 17 HARDWARE BOM 18 WIRING ENTRIES 19 INSTALLATION 20 DIMENTIONAL GENERAL ASSEMBLY 25 DISMANTLING MAINTENANCE 26 MOUNTING OPTIONS 28 ...

Page 6: ...eed for extra equipment reduces installation time reduces labor expenses and increases safety by lessening the potential for mismatched hazardous rated components Additionally the D Series are constructed with a proprietary explosion resistant polymer blend offering maximum clarity and enhance optical performance To enhance optical performance the explosion proof lens is equipped with our Virtual ...

Page 7: ...e Ring 1 S Stainless Steel 316L Housing C Internal Equipment Part Number from Manufacturer BD Optional Breather drain model Internal components and D Series must be approved by Spectrum Internal Equipment Manufacturer Code below Must be approved and verified by Spectrum Models supplied with Breather Drains will have IP66 ingress protection level CODE XX Manufacture 01 AXIS COMMUNICATIONS D201 1 Q6...

Page 8: ...Labels Option A 8 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 BREATHER DRAIN MODEL BREATHER DRAIN MODEL ...

Page 9: ...the flameproof joints is necessary Follow the manufacturer s instructions to reduce the potential of an electrostatic charging hazard on the surface of the equipment in Group II and III environments The equipment meets the requirements according to the low level risk of mechanical danger Therefore the equipment shall be located and installed such that the risk of impact or other mechanical damage ...

Page 10: ...isk of electric shock or high temperature parts may result in injury if proper precautions are not taken NOTE Emphasizes important or essential information Locating Information NOTE In the interest of completeness manuals and drawings included with the system may provide information pertaining to options not included with your equipment Information in application notes supersedes general informati...

Page 11: ...ertificates for any Special Conditions of Use If the sign X is placed after the certificate number it indicates that the equipment or protective system is subject to special conditions for safe use specified in the schedule of the certificate NOTE Review all material and safety information in this manual and install in accordance with this document and all other applicable ATEX CSA IECEx NEC NFPA7...

Page 12: ...ling and servicing any part of electrical equipment Hot components should be allowed to cool before servicing if possible Other appropriate equipment or clothing must be used as required by the type of work performed All applicable regulations and procedures must be followed for the work performed Before beginning any work on the equipment carefully consider all the potential hazards and ensure th...

Page 13: ...UTION The electrical cover should never be removed unless power is removed for at least 5 minutes from the unit or the area is known not to contain explosive materials 13 WARNING The product shall be installed by a trained professional The product shall be used in compliance with local laws and regulations Store the product in a dry and ventilated environment Avoid exposing the product to impacts ...

Page 14: ... properties of terminal housing compartment The connection to the external circuits must be realized by cable glands or pipe fittings covered by a separate certificate s If a cable gland is not used or an entry is open the entry must be closed by a stopping plug covered by a separate certificate The diameter of the cable gland is cylindrical ISO M20 x 1 5 This equipment can be used with different ...

Page 15: ...a 20 C to 55 C Type 4X IP66 67 Class II III Division 1 Groups E F G T6 Type 4X IP66 67 Ta 20 C to 55 C Class I Zone 1 AEx Ex db IIB H2 T6 Gb Ta 20 C to 55 C Type 4X IP66 67 Zone 21 AEx Ex tb IIIC T85 C Db Ta 20 C to 55 C Type 4X IP66 67 CERT NO FM18ATEX0057X IECEx FMG 18 0020X II 2 G Ex db IIB H2 T6 Gb Ta 20 C to 55 C IP66 67 II 2 D Ex tb IIIC T85 C Db Ta 20 C to 55 C IP66 67 Electrical Requiremen...

Page 16: ... consequential damages caused by use or misuse or improper installation of its products sold and assumes no liability for injury from use or misuse or improper installation of its products or attached products D201 1 Q6055 E Explosion Proof Camera Hazardous Area Voltage IEEE 802 3bt PoE 60W PoE Midspans PoE Injectors 16 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 SPECIFICATI...

Page 17: ...ve hardware 4 Install ring Gasket on terminal Housing Optional SD GK Aluminum version only 5 Install wall mount with hardware removed from step 3 Note Apply Anti seize to bolts 6 Install wall mount gasket and hardware to secure mount to wall SD GK 7 Remove foam and protective blue film Note Apply Anti seize to bolts Optional SD GK Anti Galvanic corrosion isolation gasket kit for offshore use of Al...

Page 18: ...SERIES INSTALLATION MANUAL REV 1 HARDWARE BOM 4 1 3 2 5 1 QTY 1 EXTERNAL GROUND LUG 2 QTY 3 M10 X 1 5 18 8 BOLT 3 4 SETS WEDGE LOCK WASHER 4 QTY 1 D2005 Z CLIP 5 SD WM WALL MNT NOT INCLUDED 6 M10X1 25 M10X1 5 ADAPTER 7 M10x1 25 hex nut 6 7 ...

Page 19: ...TION MANUAL REV 1 WIRING ENTRIES Conduit Entries are M20 x 1 5 Use appropriate adapter with nylon Washer or O ring to keep ingress protection level CAUTION Ensure the Ethernet cable is disconnected from power source prior to wiring to the terminal block ...

Page 20: ...era 2 Make sure threads on camera and M10x 1 5 are free of dirt and debris Place mount on camera and align holes and tighten bolts add anti seize for offshore installation 3 Attach the camera with wall mount to mounting surface Use only installation methods and materials capable of supporting four times the maximum specified load of the system D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION ...

Page 21: ...gland and seal using the recommended gland installation practices There are two conduit entries on models without the BD Breather drain option D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 Figure 2 Removing D1005 cap Conduit Entries are M20 x 1 5 Use appropriate Adapter with Nylon Washer or O ring to keep ingress protection follow guidelines of the manufacturer of gland or ada...

Page 22: ...sition 2 Orange Position 3 White Green Position 4 Blue Position 5 White Blue Position 6 Green Position 7 White Brown Position 8 Brown Table 1 Figure 5 Wire Cable Connections INSTALLATION External Ground Internal Ground Figure 6 Grounding 8 Connect ground to equipment before powering For U S zones the internal grounding connection shall be used and the external grounding connection shall be a suppl...

Page 23: ...With Nylon Washer or O ring to keep ingress protection D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 INSTALLATION CAUTION Ensure the ethernet cable is disconnected from power source prior to wiring to the terminal block Figure 3 Figure 4 ...

Page 24: ...IES INSTALLATION MANUAL REV 1 Figure 7 Installing D1005 cap Figure 8 Retaining clip order Figure 9 Final assembly INSTALLATION NOTE Do not install camera unless power is applied in near future 12 Remove protective film after installation If protective film is not removed in timely manor damage to dome is likely to occur with UV exposure 13 Apply power For internal equipment startup procedures sett...

Page 25: ...Dimensional General Assembly 25 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 ...

Page 26: ... dish soap and water Lastly apply coating of Repel by Unelko corporation surface cleaner Never use harsh chemicals or abrasive towels Replacing the battery The Axis Q6055 E product uses a 3 0 V CR2032 lithium battery Lithium primary battery composed of cathode from carbon monofluoride anode from lithium and electrolyte from organic solvent and lithium salt as the power supply for its internal real...

Page 27: ...bt PoE Power over Ethernet standard 57Vdc max Voltage and wattage shall not exceed the maximum tested configuration of 57Vdc 60W The D Series Network Ethernet Cameras are rated for use in an ambient temperature range of 20 C to 55 C and are IP66 67 IP67 is not applicable when supplied with optional breather drain The camera within the enclosure may be placed in any arrangement provided that an are...

Page 28: ... PoE Power over Ethernet standard 57Vdc max Voltage and wattage shall not exceed the maximum tested configuration of 57Vdc 60W The D Series Network Ethernet Cameras are rated for use in an ambient temperature range of 20 C to 55 C and are IP66 67 IP67 is not applicable when supplied with optional breather drain The camera within the enclosure may be placed in any arrangement provided that an area ...

Page 29: ...SD WM WALL MOUNT 29 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 ...

Page 30: ...SD PMA POLE MOUNT ADAPTER 30 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 HARDWARE QTY 4 7 8 20 18 8 Bolts QTY 2 12in all thread with nuts and washers QTY 2 A1612 sides ...

Page 31: ...SD CM CORNER MOUNT 31 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 HARDWARE QTY 4 7 8 20 18 8 Bolts ...

Page 32: ...SD VM VIBRATION MOUNT 32 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 HARDWARE QTY 4 7 8 20 18 8 Bolts FRONT ...

Page 33: ...SD SO STANDOFF MOUNT 33 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 HARDWARE QTY 4 7 8 20 18 8 Bolts FRONT BACK ...

Page 34: ...ASSEMBLY MOUNTS 34 D201 1 Q6055 REV 4 105607312018 D SERIES INSTALLATION MANUAL REV 1 SD CM SD PMA SD CM SD VM SD SO SD PMA ...

Reviews: