Dismantling:
It is not recommended to open the main camera housing. All repairs of explosion-proof
equipment must be made according the specified criteria of IEC/EN 60079-19 rule by qualified
personnel, having knowledge concerning electrical equipment for potentially explosive areas
containing gas and/or dust. Qualified personnel must have knowledge regarding the types of
explosion protection.
Maintenance:
The maintenance must be realized in accordance with IEC/EN 60079-17 and/or in accordance
with the national requirements. Contact Spectrum Camera for training program to properly
open and close the main camera housing.
Cleaning lens-
Washdown dome with distilled water first to avoid partials scratching the
surface. Clean lens with damp microfiber cloth with mild dish soap and water. Lastly, apply
coating of Repel (by Unelko corporation) surface cleaner. Never use harsh chemicals or
abrasive towels.
Replacing the battery- The Axis Q6055-E product uses a 3.0 V CR2032 lithium battery Lithium
primary battery composed of cathode from carbon monofluoride anode from lithium and
electrolyte from organic solvent and lithium salt as the power supply for its internal real-time
clock (RTC). Under normal conditions this battery will last for a minimum of five years. Low
battery power affects the operation of the RTC, causing it to reset at every power-up. When the
battery needs replacing, a log message will appear in the product’s server report. For more
information about the server report, see the product´s setup pages or contact Spectrum support.
The battery should not be replaced unless required. If required contact
support@spectrumcamera.com
26
D201-1-Q6055 REV 4 105607312018 D SERIES
INSTALLATION MANUAL REV-1
DISMANTLING & MAINTENANCE