SPECIFICATIONS
Environmental Conditions
(Equipment must be powered)
OPERATIONONAL CONDITIONS
USE
For Indoor and Outdoor Use
15
CERTIFICATIONS of Model- D201-S-Q6055-E-BD
CERT
NO. FM17US0156 & FM18CA0103X
Class I Division 1 Groups B,C,D T6, Ta = -20°C to +55°C Type 4X, IP66
Class II/III, Division 1, Groups E,F,G T6 Type 4X, IP66/67 Ta = -20°C to +55°C
Class I, Zone 1, AEx/Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, Type 4X, IP66
Zone 21, AEx/Ex tb IIIC T85°C Db Ta = -20°C to +55°C, Type 4X, IP66
CERT NO. FM18ATEX0057X & IECEx FMG 18.0020X
II 2 G Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, IP66
II 2 D Ex tb IIIC T85°C Db Ta = -20°C to +55°C, IP66
ELECTRICAL REQUIREMENTS of Model- D201-S-Q6055-E-BD
POWER
INPUT/CONSUMPTION
CAMERA CONSUMPTION: TYPICAL 16W, MAX 60W
Voltage
44-57 Vdc 60W over 4-pairs
105607312018 D201-x-Q6055-E
INSTALLATION MANUAL REV-1