9. Ensure threads on D1005 terminal cap and D1006 Terminal housing are free of dirt and debris.
10. Ensure gasket is free of dirt and debris
11. Reinstall D1005 terminal cap using supplied M5 supplied Hex tool to tighten by turning
clockwise until hand tight and gasket is seated
12. In the following order install D2005 housing retainer clip, wedge lock washers, and nut. Ground
lug is at bottom of thread adapter See figure 8-9
Figure 7.
Installing D1005 cap
Figure 8.
Retaining clip order
Figure 9.
Final assembly
INSTALLATION
105607312018 D201-x-Q6055-E
INSTALLATION MANUAL REV-1