2.  Remove the SPECTRUM Gas Char Broiler from the packaging. Be certain 

that all protective plastics and residues are thoroughly cleaned from its 

surface.

3.  Place the SPECTRUM Gas Char Broiler on a firm level surface. Local 

standards and regulations should be consulted in order to abide by 

standards set in relation to positioning, spacing, and ventilation. 

4.  Ensure gas supply and gas type, as shown on unit nameplate, agree.
5.  Unit installation must conform with the National Fuel Gas Code, ANSI 

Z223.1/NFPA 54, the National Gas Installation Code, CSA-B149.1, or the 

Propane Installation Code, CSA-B149.2 as applicable and in accordance 

with local codes.

6.  Screw legs into the permanently fastened nuts on the four corners of 

the unit and tighten by hand. Level the unit by turning the adjustment 

screw at the bottom of each leg. Do not slide unit with legs mounted; 

lift if necessary to move unit.

7.  Pipe threading compound must be resistant to the action of liquefied 

petroleum gases.

 

CAUTION • ATTENTION

   

DO NOT use an open flame to check for leaks. Check all gas piping 

for leaks with a soap and water solution before operating unit.

NE PAS utiliser une flamme nue pour vérifier les fuites. Vérifiez tous les 

tuyaux de gaz pour les fuites avec de l'eau savonneuse avant de l'unité 

d'exploitation.

ThESE UNITS ARE SUITABLE FOR INSTALLATION ON  

NON-COMBUSTIBLE SURFACE-S ONLy.

Combustible clearances:

6" sides (152 mm)  6" rear (152 mm)  4" floor (102 mm)

Noncombustible clearances:

0" sides (0 mm) 

0" rear (0 mm) 

4" floor (102 mm)

ThiS EquiPmENT gETS EXTREmELY hOT. DO NOT POSiTiON AND OPERATE 

NEAR cOmbuSTibLE mATERiALS/fLAmmAbLE ObjEcTS. 

Do not obstruct the flow of combustion and ventilation air, under the unit by 

the legs or behind the unit by the flue. 

Ne pas obstruer le flux de combustion et de ventilation, sous l'unité par les jambes ou 

derrière l'appareil par la cheminée. 

Adequate clearance for air openings into the combustion chamber is 

required. Do not place objects between the bottom of the unit and the 

counter top. 

Un dégagement adéquat pour des ouvertures d'air dans la chambre de combustion 

est nécessaire. Ne pas placer d'objets entre le bas de l'appareil et le comptoir.

There must be adequate clearance for removal of the front panel. All major 

parts except the burners are removable through the front if the gas line is 

disconnected.

Il doit y avoir un espace suffisant pour le retrait de la face avant. Toutes les parties 

principales à l'exception des brûleurs sont amovibles à travers l'avant si la conduite 

de gaz est coupée.

These instructions should be followed at all times. Failure to follow these 

instructions could result in injury to yourself and others.

TO REDUCE RISK OF INJURy OR DAMAGE TO ThE UNIT:

1.  Read this manual thoroughly before installation and operation. DO NOT 

proceed with installation and operation if you have any questions or do 

not understand anything in this manual. Contact your representative or 

the manufacturer first.

TO AVOID SERIOUS PERSONAL INJURY:

•  ALWAYS install equipment in a work area with adequate light  

and space.

•  ONLY operate on a solid, level, nonskid surface.
•  NEVER bypass, alter or modify this equipment in any way from  

its original condition. Doing so can create hazards and will  

void warranty.

•  NEVER operate the char broiler without all warnings attached to it.

Fire hazard.

Correct installation precautions, 

procedures and regulations 

must be followed. Operation 

and safety training is necessary 

for all users of this equipment.

Risque d'incendie

La surchauffe des vapeurs d'huile ou de 

l'huile peut s'enflammer et provoquer 

un incendie. Surveillez la température, 

la qualité et le niveau d’huile. Utilisez et 

entretenez le système d'élimination des 

vapeurs d'huile.

The equipment must be 

installed by qualified personnel 

only. Correct installation 

precautions, procedures and 

regulations must be followed 

in order to reduce the risk of 

fire. Hood and fire suppression 

systems must be maintained 

per manufacturer's guidelines. 

Only qualified and trained 

personnel are to use this 

equipment.

Faire chauffer l'huile avec précaution. Si 

l'huile fume, réduire le feu. Ne pas laisser 

l'appareil sans surveillance. Si le feu se 

produit, éteindre l'appareil, couvrir jusqu'à 

refroidissement. Ne pas mettre l'eau dans 

l'huile chaude ou enflammée. Ne faites pas 

fonctionner avec de l'huile sous la barre 

d'huile. L’huile sale a un point d'éclair 

plus bas. Remplacer l'huile sur une base 

régulière. Maintenir le niveau d'huile 

correct. Utiliser un système d'évacuation 

de la vapeur d'huile (capot) pour réduire 

l'accumulation de graisse et d'huile sur les 

surfaces de paroi ou de plafond.

WARNING

AVERTISSEMENT

Burn hazard.

When in operation, the 

Conveyor Toaster will be hot at 

the entrance to the conveyor 

cavity. 

Please take extreme caution.

Risque de brûlure.

Ne touchez pas les surfaces chaudes ou 

chauffées liguid tout appareil chauffe ou 

en fonctionnement.

USE CAUTION WhEN 

TOUChING ThE UNIT.

Ne touchez pas le liquide chaud 

ou les surfaces de chauffage 

lorsque l’appareil chauffe ou en 

fonctionnement.

WARNING

AVERTISSEMENT

HOT

Summary of Contents for GCB-24R

Page 1: ...est results it is important that you read and follow the instructions in this manual carefully It s important to save these instructions for future reference GCB 36R GCB 24R 3182799 Conforms to ANSI STD Z83 11b 2009 R2012 Certified to CSA STD 1 8b 2009 R2012 MODEL WIDTH IN MM DEPTH IN MM HEIGHT IN MM OF BURNERS BTU PER NAT LP TOTAL BTU HR PRESSURE IN W C GCB 24R 24 610 mm 26 8 680 mm 15 6 398 mm 2...

Page 2: ...structionsmustbepostedinaprominent location Allsafetyprecautionsmustbetakeninthe eventtheusersmellsgas Safetyinformationcanbe obtainedfromyourlocalgassupplier AVERTISSEMENT Lesinstructionsdoitêtreaffichéesdans unendroitbienenvue Touteslesmesuresdesécurité doitêtreprisesencasd odeurdegaz Lesconsignes desécuritépeutêtreobtenueauprèsdevotrefournisseur degazlocal WARNING Afactoryauthorizedagentshouldh...

Page 3: ... LOCATIONOFDATAPLATE Thedataplateislocatedonthesidepanel IMMEDIATELYINSPECTFORSHIPPINGDAMAGE Allcontainersshouldbeexaminedfordamagebeforeandduringunloading Thefreightcarrierhasassumedresponsibilityforitssafetransitanddelivery Ifequipmentisreceiveddamaged eitherapparentorconcealed aclaim mustbemadewiththedeliveringcarrier A Apparentdamageorlossmustbenotedonthefreightbillatthetimeof delivery Itmustt...

Page 4: ... AVERTISSEMENT Cesymboleindiqueundangerpotentiel ouunepratiquedangereuse quipeutentraînerdes blessuresgravesoulamort CAUTION Thissymbolreferstoapotentialhazard orunsafepractice whichcouldresultinminoror moderateinjuryorproductorpropertydamage ATTENTION Cesymboleindiqueundangerpotentielouune pratiquedangereuse quipeutentraînerdesblessures mineuresoumodéréesoudesdommagesmatériels NOTICE Thissymbolre...

Page 5: ...desbrûleurssontamoviblesàtraversl avantsilaconduite degazestcoupée Theseinstructionsshouldbefollowedatalltimes Failuretofollowthese instructionscouldresultininjurytoyourselfandothers TO REDUCE RISK OF INJURY OR DAMAGE TO THE UNIT 1 Readthismanualthoroughlybeforeinstallationandoperation DONOT proceedwithinstallationandoperationifyouhaveanyquestionsordo notunderstandanythinginthismanual Contactyourr...

Page 6: ...a1 2 spanner Seethelistof orificenumbersfortheappropriategastype TheseinstructionsarefortheconversionfromNaturalGastoPropane L P onallmodels Theconversionshouldbedonebeforeconnectingtheunitto thegassupply Unitsareshippedfromthefactoryequippedforuseonnaturalgas Orifices necessaryforPropane L P areincludedwiththeunit 1 Shut offthemainisolationgasvalveand followthelock out tag outprocedure Screw Main...

Page 7: ...lovestorepositionorremove Thespacebetweenthelegsatthebottomadmitscombustionair DONOTBLOCKTHISSPACE Netentezjamaisdedéplacerunesectiondelagrillependantlacuisson Unefusée inattendupourraitcauserdesblessuresgraves Eteignezl appareil lelaisserrefroidir etemployerdesgantsisolantset oudesgantspourrepositionnerousupprimer L espaceentrelesjambesenbasadmetl airdecombustion NEPASBLOQUERCETESPACE Allburnersa...

Page 8: ...llysufficient DAILYCLEANING Removethegreasepan emptyandwashit Thegreasebuilduponthegrates shouldbecleaneddaily moreoftenasneeded CAUTION ATTENTION Whenhandlinggratesorradiants alwaysuseinsulated glovestopreventburns Lorsdelamanipulationdesgrillesouradiants utilisez toujoursdesgantsisolantspouréviterlesbrûlures WARNING ADVERTISSEMENT Donotcoverthetopofthegridgratesduringaburnoff operation Restricti...

Page 9: ...Coverthefoodwithenoughoiltopreventstickingtothe grates Foodisundercookedinside Heatissettoohigh Decreasetheburnerflame Foodmaynothavebeencookedforlongenoughtime Provideenoughtimeforthefoodtocook Foodtastesgreasyorhas objectionableoff flavor Fooditselfmayhaveoffflavor Makesuretochecktheexpirationdateofthefoodbefore cooking Foodmayhavebeenstoredimproperlybeforecooking Makesuretostorethefoodproperlya...

Page 10: ...10 Exploded View Model GCB 36R ...

Page 11: ...ptional GCB P3 3 GCB P3 2 3 Regulator GHP P3 1 GHP P3 1 4 Burner GCB P5 3 GCB P5 2 5 Foot GHP P5 4 GHP P5 4 6 Tray GCB P7 36 1 GGD P4 1 7 PilotPipe GCB P8 3 GCB P8 2 8 Pilotvalve GCB P9 3 GCB P9 2 9 ValveforManual GHP P11 3 GHP P11 2 10 Dial GHP P12 3 GHP P12 2 11 OrificeforNaturalGas GCB P12 3 GCB P12 2 OrificeforLPG GCB P13 3 GCB P13 2 12 12 CastLavaRockKit Optional GCB LRRC 3 GCB LRRC 2 ...

Page 12: ...GES WHETHERINNEGLIGENCE WARRANTY STRICTLIABILITY OR OTHERWISE Thiswarrantyisgivenonlytothefirstpurchaserfromaretaildealer Nowarrantyisgiventosubsequenttransferees Warrantydoesnotcoverproductfailurescausedby failuretomaintain neglect abuse damageduetoexcesswater fire normalwear impropersetupanduse Periodicmaintenanceisnotcovered Thiswarrantyisnotinforceuntilsuchtimeasaproperlycompleted anddigitally...

Reviews: