InView Display Mounting

The following instructions provide panel cutout dimensions for the InView P22R 
Panel Mount Display. 

The InView P22R mounts in a custom panel or enclosure. When it is properly 
installed, the faceplate provides a NEMA Type 12, 13, and 4X(indoor) rating. To 
install the InView Display:

1.

Cut and drill the appropriate mounting holes in the enclosure or panel.

2.

Remove the six mounting nuts from the hardware bag provided with the 
display.

3.

Position the InView Display in the panel or enclosure mounting hole.

4.

Install nuts and alternately tighten the nuts to a torque of 0.904 Nm (8 in-lb).

Panel Cutout Dimensions 

Cutout 345.9 (13.62)

Cutout

 

173.0 (6.81)

98.4

 

(3.88)

352.3 (13.87)

Cutout

 

88.9

 

(3.50)

176.3 (6.95)

4.8 (0.19)

4.8 (0.19)

 6.4 (0.25)

 

Diameter 
Hole

 

6 places

2706-P22R Display