background image

 

3 | 

P a g e

 

 

Spedo Optical Loop Interface 2232 Instruction Manual 

 

Spedo Optical Loop Interface 2232 

Publisher 

Published by Spedo UK Limited 

76 Woolmer Way 

Bordon 

Hampshire 

GU35 9QF 

ENGLAND 

Copyright 

Spedo UK Limited 2013 

All Rights Reserved. 

No  part  of  this  publication  may  be  reproduced,  stored  in  a  retrieval  system,  or 
transmitted,  in  any  form  or  by  any  means,  electronic,  mechanical,  photocopying, 
recording, or otherwise, without the prior written permission of Spedo UK Limited. 

Unpack 

Unpack the equipment and examine it thoroughly to ascertain whether any damage 
has  occurred  in  transit.  Report  immediately  any  such  damage  to  the  agent  or 
manufacturer.  Retain the packing should further transportation be necessary. 

All Goods 

All  goods  manufactured  by  the  Company  are  guaranteed  to  the  extent  hereafter 
mentioned  against  defects  arising  from  faulty  material  or  workmanship  subject  to 
the goods not having suffered maltreatment or interference. The Company's liability 
under this guarantee is limited to replacing any part or parts found defective within a 
period as laid down in Company instructions after the date of delivery or installation. 

Other Goods 

If  goods  not  of  the  Company's  manufacture  are  ordered,  the  guarantee  of  that 
company is to be accepted. 

Descriptive Matter 

Descriptive matter, illustrations, dimensions and weights issued by the Company are 
typical and shall not be held as binding. 

Patterns and Designs 

The Company reserves the right to alter patterns and designs without notice. 

First Published  
January 2013 

We  have  taken  every  care  in  the  preparation  of  this  manual.  If  there  are  any 
inaccuracies,  ambiguities  or  omissions,  Spedo  UK  Limited  and  its  consultants  and 
distributors  cannot  accept  responsibility  for  any  loss  or  damage  these  errors  may 
cause. 

 

Summary of Contents for Issue 2

Page 1: ...1 Spedo Optical Loop Interface 2232 Instruction Manual Spedo Optical Loop Interface 2232 Instruction Manual Issue 2 Spedo UK Limited 76 Woolmer Way Bordon Hampshire GU35 9QF ENGLAND Telephone 44 0 1420 487 447 Fax 44 0 1420 477 827 Email spedo spedouk com Web www spedouk com ...

Page 2: ... P a g e 2 Spedo Optical Loop Interface 2232 Instruction Manual Spedo Optical Loop Interface 2232 History Sheet Manual Issue Date Changes Incorporated 1 January 2013 First Issue 2 May 2015 Format Changed ...

Page 3: ...extent hereafter mentioned against defects arising from faulty material or workmanship subject to the goods not having suffered maltreatment or interference The Company s liability under this guarantee is limited to replacing any part or parts found defective within a period as laid down in Company instructions after the date of delivery or installation Other Goods If goods not of the Company s ma...

Page 4: ...lowed by the user to ensure safe operation and to retain the equipment in a SAFE condition All users of the equipment described in this manual MUST have received adequate training in its use and application in order to ensure SAFE AND PROPER USE Any adjustment maintenance or repair of the opened apparatus under voltage shall be carried out only by a skilled person who is AWARE OF THE HAZARD INVOLV...

Page 5: ...ight 3 Safety Measures 4 Table of Contents 5 DESCRIPTION AND OPERATION SECTION 1 INTRODUCTION 6 TECHNICAL DATA 6 DESCRIPTION OF OPERATION 7 Optical Loop Interface Unit 7 Operation with Ancillary Units 7 INSTALLATION 8 OPERATING INSTRUCTIONS 9 Paper Detection Range Adjustment 9 Printer Output Delay Adjustment 10 OPERATIONAL MAINTENANCE 11 ...

Page 6: ...orms cutter of other manufacture can be used provided it is fitted with a synchronisation input facility The unit is positioned on the floor mounted on 4 feet between the two units Fig 1 1 Spedo Optical Loop Switch 2232 TECHNICAL DATA Paper Loop Sync Switched relay contact normally open Closed across pins 1 3 when paper is detected Mains Power 240 V 10 50 60 Hz Mains Fuse 800 mA Type F800mA Dimens...

Page 7: ...be adjusted internally Fig 1 2 Identification of Main Parts Operation with Ancillary Units Optical Loop Interface Unit is supplied with mains power from the forms cutter by interconnecting it with the mains lead supplied The sync lead is also connected to the forms cutter Several cables are provided for interfacing with input devices and care must be taken to ensure the correct cable is used Both ...

Page 8: ... ADEV RUN and the ADEV READY indicators are illuminated Place a piece of paper in front of the cutter control sensor and check that at a maximum of 300 mm the CUTTER RUN indicator toggles on and off as the paper is moved inside and outside the sensing range Place a piece of paper in front of the printer control sensor and check that at a maximum of 100mm the ADEV RUN indicator toggles on and off N...

Page 9: ...ciated indicator are housed on the opto sensor assembly and can only be accessed from inside the unit With the mains power disconnected remove x6off M4x12 screws and carefully lift off the top cover Note this cover is attached to cables which connect directly to control board Fig 1 4 Paper Detection Range Adjustments The adjustment control and indicator are located at the end of the opto sensor Th...

Page 10: ... 5 With the mains power disconnected remove x6off M4x12 screws and carefully lift off the top cover Note this cover is attached to cables which connect directly to control board Fig 1 5 Printer Output Delay Adjustments Reconnect the mains power Adjust the potentiometer VR1 R8 on earlier models Test the reaction time of the printer control sensor by covering and uncovering and checking the delay on...

Page 11: ...s equipment Ensure that the equipment is isolated from the mains supply when carrying out any maintenance procedures Cleaning This is limited to removing the build up of paper dust with an airline from the face of the opto sensor This should be carried out on a regular basis Connectors Periodically check the connectors for bent or dirty pins ...