Speedaire Operating Instructions and Parts Manual
1WC94
Speedaire
®
“Site Boss” Air Compressor
E
N
G
L
I
S
H
14
BEFORE EACH START-UP:
1. Place On/Auto/Off lever
to “OFF”.
2. Pull regulator knob out,
turn counterclockwise
until it stops. Push knob
in to lock in place.
3. Attach hose and acces-
sories.
NOTE:
See PORTABLE
“QUADRAPORT” CONTROL
PANEL paragraph in the
Installation section of this
manual.
NOTE:
The hose or accessory
will require a quick connect
plug if the air outlet is
equipped with a quick con-
nect.
HOW TO START:
1. Turn the On/Auto/Off
lever to “AUTO” and
allow tank pressure to
build. Motor will stop
when tank pressure reach-
es “cut-out” pressure.
Too much
air pressure causes a haz-
ardous risk of bursting.
Check the manufacturer’s
maximum pressure rating
for air tools and acces-
sories. The regulator out-
let pressure must never
exceed the maximum
pressure rating.
2. Pull the regulator knob
out and turn clockwise to
increase pressure. When
the desired pressure is
reached push knob in to
lock in place. The com-
pressor is ready for use.
NOTE:
Always operate the
air compressor in well-venti-
lated areas free of gasoline
or other combustible vapors.
If the compressor is being
used to operate a sprayer
DO NOT place near the spray
area.
Maintenance
CUSTOMER
RESPONSIBILITIES
Daily or
after
each
use
Before
each
use
●
●
●
Every
40
hours
Every
100
hours
Yearly
●
1
(1) more frequent in dusty or humid conditions
Check Safety Valve
Drain Tank
Air Filter
Air compressor pump intake and
exhaust valves
●
Operation
(Continued)