19
E
N
G
L
I
S
H
Speedaire Operating Instructions and Parts Manual
Model 1WC95
Regulator will
not shut off air
outlet
Damaged regulator
Replace
Damaged regulator
Replace
Regulator knob
has continuous
air leak
Symptom (s)
Possible Causes (s)
Corrective Actions (s)
Motor will not
run
1. Motor overload protection
switch has tripped
1. Let motor cool off and overload
switch will automatically reset
2. Tank pressure exceeds pres-
sure switch “cut-in” pressure
2. Motor will start automatically
when tank pressure drops below
“cut-in” pressure of pressure switch
3. Extension cord is wrong
length or gauge
3. Check for proper gauge wire and
cord length
5. Loose electrical connections
5. Check wiring connection inside
pressure switch and terminal box
area
6. Have checked by a trained service
technician
4. Check valve stuck open
4. Remove and clean, or replace
6. Possible defective motor or
starting capacitor
7. Have checked by a trained service
technician. Do not operate the
compressor in the paint spray area.
See flammable vapor warning
7. Paint spray on internal motor
parts
8. Bleed the line by pushing the lever
on the pressure switch to the “off”
position; if the valve does not
open, replace switch
8. Pressure release valve on
pressure switch has not
unloaded head pressure
Troubleshooting Chart (Continued)
Summary of Contents for 1WC95
Page 77: ...Notes Manuel D utilisation et de Pièces Détachées Speedaire 1WC95 F R A N Ç A I S 23 Fr ...
Page 82: ...Notes Manuel D utilisation et de Pièces Détachées Speedaire 1WC95 F R A N Ç A I S 28 Fr ...
Page 83: ...Notes Manuel D utilisation et de Pièces Détachées Speedaire 1WC95 F R A N Ç A I S 29 Fr ...