Speedaire
®
Diaphragm Compressor Pump
.
Type/
Model
up to 150 mbar
(2.2PSI)
max. working
pressure*
up to 200 mbar
(2.9PSI)
max. working
pressure*
up to 250 mbar
(3.6PSI)
max. working
pressure*
26X359
26X360
24Months
18 Months
12-18 Months
26X361
26X362
24 Months
18 Months
12-18 Months
Do not use gasoline or thinner to clean the
filter element as it can be damaged.
c.
Make sure that no particles and/or bends etc. are left
in the piping after its construction. Extra pressure
caused by foreign substances left in the piping will
be applied on the compressor pump, which will
result in the compressor pump overheating. It may
shorten the life of diaphragms and valves.
d.
Connect the compressor pump to the air piping with
the
accessory
L-Type-hose,
and
secure
the
connection with a hose clamp.
e.
Make sure, that the max. backpressure is no more
than 200mbar (2.9 PSI) for 26X359 and 26X360 and
250mbar (3.6 PSI) for 26X361 and 26X362.
4. Operating Instructions
a.
Do not touch the power plug with wet hands.
b.
Disconnect all appliances in the aquarium or pond
from the main power supply before putting your
hands into the water.
a.
Disconnect the power cord by holding the power
plug.
b.
Do not wash the compressor pump with water.
Maintenance
Prior to maintenance servicing, pull out
the power cord.
1. Occasional Checks
Is air blowing out properly?
Is the compressor pump making abnormal
noise or vibrations?
Is the temperature of the compressor pump
abnormally high?
Is the power cord or the plug damaged,
swelled or discolored?
If any irregularity is found, see Troubleshooting Chart
(page 7)
2. Maintenance Frequency
Change the filter element, valve boxes and diaphragms
every 12-18 months