background image

Form 5S3191

Description

Speedaire one cylinder, low maintenance, oil-less portable air compressor is
designed for home, farm, and medium duty industrial uses with a 50/50 duty cycle.
The 2 HP pump and motor assembly on a 3 gallon capacity air tank is equipped
with check valve, unloader valve, pressure switch, safety valve, air regulator, and a
tank pressure gauge. Motor includes automatic thermal overload protection. UL
listed.

Printed in U.S.A.
03465
0899/287/VCPVP

Breathable Air Warning

This compressor/pump is not
equipped and should not be
used “as is” to supply
breathing quality air. For any
application of air for human
consumption, the air
compressor/pump will need to
be fitted with suitable in-line
safety and alarm equipment.
This additional air to meet
minimal specifications for Grade
D breathing is described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910.134 in
the United States  and/or
Canadian Standards Association
(CSA).

DISCLAIMER OF WARRANTIES

In the event the compressor is
used for the purpose of
breathing air application and
proper in-line safety and alarm
equipment is not
simultaneously used, existing
warranties shall be voided, and
Dayton Electric Mfg. Co.
disclaims any liability
whatsoever for any loss,
personal injury or damage.

E

N
G

L

I

S

H

®

Specifications

Motor HP ......................................................... 2

Cylinders ..................................................... One

Air Delivery - SCFM @ 40 psi ........................ 4.5

Air Delivery - SCFM @ 90 psi ........................ 3.2

Maximum Air Pressure (psi) ...................... 135

Compressor RPM ...................................... 1725

Tank Size (Gallons) .......................................... 3

Voltage @ 60 Hz, 1-Phase ......................... 120

Amperage (Amps) ........................................ 15

Overall Dimensions

 

L      W     H        Weight

26”   8”    19”    39 lbs.

Figure 1

Never spray in a
closed area. Motor

and pressure switch may spark when
operating, if sparks come in contact
with vapors from  gasoline,
flammable paint or solvents, they
may ignite causing fire or explosion.

3.

Do not adjust, remove, or tamper
with the safety valve or pressure
switch. If safety valve or pressure
switch replacement is necessary, a
part with the same rating must be
used.

Unpacking

After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Check for loose,
damaged or missing parts.

General Safety Information

1.

Never touch the air compressor
head during or immediately after
operation.

2.

Operate compressor in a well
ventilated area that is free of
gasoline, flammable paint or solvent
vapors. If spraying a flammable
material, provide ample ventilation.

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.

  Operating Instructions & Parts Manual

 

                          

5Z598C

Speedaire Portable Air
Compressor

®

D23820-1

#721Y

Summary of Contents for 5Z598C

Page 1: ...S H Specifications Motor HP 2 Cylinders One Air Delivery SCFM 40 psi 4 5 Air Delivery SCFM 90 psi 3 2 Maximum Air Pressure psi 135 Compressor RPM 1725 Tank Size Gallons 3 Voltage 60 Hz 1 Phase 120 Amp...

Page 2: ...t sure about the use of a certain mask or respirator 12 If the material you intend to spray contains trichloroethane and methylene chloride read the label or the data sheet do not use accessories that...

Page 3: ...what is required at the air outlet CHECK VALVE When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches cut out pressu...

Page 4: ...tilated areas free of gasoline flammable paint or solvent vapors Do not operate the compressor near a spray area Maintenance Unit cycles automatically when power is on When preforming maintenance you...

Page 5: ...use of products for certain purposes which may vary from those in neighboring areas While Dayton attempts to assure that its products comply with such codes it cannot guarantee compliance and cannot b...

Page 6: ...there is pressure in the tank and the compressor is shutoff Remove and clean or replace check valve DO NOT OVER TIGHTEN Air tank must be replaced Do not repair the leak DO NOT DRILL INTO WELD OR OTHE...

Page 7: ...d replace if required 5 Remove and clean or replace 6 Tighten fittings See Air Leaks Section of Troubleshooting Chart 1 Let motor cool off and overload switch will automatically reset 2 Motor will sta...

Page 8: ...For Replacement Parts Call 1 800 323 0620 24 hours a day 365 days a year Please provide following information Model number Serial number if any Part description and numbers as shown in parts list Addr...

Page 9: ...assembly 1 4 18 NPT Nipple 150 psig Safety valve Line cord Sleeve nut of 1 4 O D tube Pressure relief tube Pressure switch 1 4 18 NPT x 1 1 2 Nipple Washer Rubber foot Screw Drain valve Insert tube i...

Page 10: ...s a day 365 days a year Please provide following information Model number Serial number if any Part description and numbers as shown in parts list Address parts correspondence to Grainger Parts P O Bo...

Page 11: ...y 1 4 20 unc 2A Screw Fan 1 4 20 unc x 75 Screw n 10 24 x 75 T75 Torx Screw n Rod cap n Compression ring l Air filter kit s Piston cylinder kit n Cylinder sleeve compression ring 2 DAC 143 1 2 1 AC 00...

Page 12: ...____________________________________ _____________________________________________________________________________________________________________________ _____________________________________________...

Reviews: