7
OPERATING INSTRUCTIONS
Break in the pump (Fig D):
1. Set the ON/OFF switch (1) to the OFF position.
2. Open tank drain valve (4) by turning it counter-clockwise to permit the
air to escape and prevent air pressure build-up in the air tank during
the break-in period.
3. Turn the air pressure regulator (5) clockwise until it stops.
4. Plug in the power cord (2).
a. Use a dedicated circuit. The compressor will use the full capacity of
a typical 15A household circuit. If any other electrical devices are
drawing from the compressor's circuit, the air compressor may fail to
start, especially in cold conditions.
b. Disconnect the power cord only after break-in process has been
completed, otherwise the motor might get damaged.
5. Set the ON/OFF switch (1) to the ON position. The compressor will
start. Run the compressor for 30 minutes. If it fails, turn it off
immediately and call the toll-free helpline at:
1-800-323-0620
.
Please note that breaking-in the unit is only requiresd prior to first
use.
6. After 30 minutes, turn off the ON/OFF switch.
7. Close the tank drain valve (1) by turning it clockwise.
8. Set the ON/OFF switch (1) to the ON position. The air receiver will fill
to "cut-out" pressure and then the compressor's motor will stop.
The compressor is now ready for use.
GETTING STARTED
SAFETY /
SPECIFICATIONS
ASSEMBLY /
INSTALLATION
OPERATION
TROUBLESHOOTING
MAINTENANCE /
REPAIR
Before each start-up (Fig D and E):
1. Set the ON/OFF switch (1) to the OFF position.
2. Turn the air pressure regulator (5) counter-clockwise until it
stops.
3. Attach air hose/accessories or air tools (not included) to the air line
outlet.