Read and understand all instructions before using the unit. Failure to follow all instructions listed 
below may result in electric shock, fire and/or serious personal injury.

Save these Instructions!!

•  Always check the unit, hoses, fittings, etc. before each use.
•  Do not fill with gasoline or any other flammable liquid. Do not operate in explosive 

atmospheres, such as in the presence of flammable liquids, gases or dust.

•  Make sure that there is adequate ventilation in the work area.
•  Stay alert, watch what you are doing and use common sense when operating this unit.
•  Keep bystanders, children, and visitors away while operating this unit.
•  Turn unit off and relieve pressure in the hose when done.
•  Do not use while tired or under the influence of drugs, alcohol, or medication.
•  Be careful — a fully filled unit is heavy! Do not make any sudden movements when using 

this unit with the shoulder strap.

•  Do not overreach or stand on unstable support. Keep proper footing and balance at all times.
•  Wear rubber gloves, rubber boots, goggles or face-shield, etc. Detergents and 

chemicals may cause injuries to the eyes and skin. Protect yourself from direct skin 
contact with the chemicals and debris found in the coil cleaning environment.

• 

Do not use any acid or cleaners that contain sodium or potassium hydroxide! 

Call 

SpeedClean to check compatibility before using any chemical in the CoilJet

®

.

• 

Do not mix chemicals!

 Mixing incompatible chemicals may cause damage to the unit or 

cause dangerous, life-threatening chemical reactions.

•  Do not use the unit if it does not operate properly or has been damaged. Do not try to 

service the unit yourself — call SpeedClean for assistance. Service must be performed 
only by qualified repair personnel. Service performed by unqualified personnel could 
result in a risk of injury and voids the warranty.

•  Never point the spray gun at anyone. Do not direct stream at eyes or mouth.
•  Always turn machine off after use or when tank is empty. Do not spray the unit with 

water or chemicals.

•  Do not allow the unit to freeze or leave in freezing temperatures.
•  Do not use water with a temperature of more than 140°F (60°C).
•  Use only approved accessories and replacement parts.
•  Follow maintenance procedures outlined in this manual. 

Important Safety Instructions

CJ-200E

Grounding Information

CJ-200E

This product must be grounded. If it should malfunction or break down, grounding provides 
a path of least resistance for electric current to reduce the risk of electric shock. This product 
is equipped with a cord having an equipment-grounding conductor and a grounding plug. 
The plug must be plugged into an appropriate outlet that is properly installed and grounded in 
accordance with all local codes and ordinances. 

DANGER:

 Improper connection of the equipment-grounding conductor can result in a risk of 

electrocution. Check with a qualified electrician or service personnel if you are in doubt as to 
whether the outlet is properly grounded. 

DO NOT USE ANY TYPE OF ADAPTOR WITH THIS PRODUCT.

Summary of Contents for CoilJet CJ-200E

Page 1: ...SpeedClean Innovative Maintenance Tools OPERATING MAINTENANCE INSTRUCTIONS U S Patent 9 381 549 MODEL CJ 200E CoilJet Portable HVAC Coil Cleaning System ...

Page 2: ...reserves the right to improve products Contact the factory for the latest configuration and uses Table of Contents Limited Warranty CJ 200E Limited Warranty 2 Important Safety Instructions 3 Grounding Information 3 Parts Breakdown 5 Common Optional Accessories 5 Operating Instructions 6 Pre Operation Checklist 6 Normal Coil Cleaning Operation 6 Chemical Dilution Ratios 6 Water Sources 6 Warnings 7...

Page 3: ...ix chemicals Mixing incompatible chemicals may cause damage to the unit or cause dangerous life threatening chemical reactions Do not use the unit if it does not operate properly or has been damaged Do not try to service the unit yourself call SpeedClean for assistance Service must be performed only by qualified repair personnel Service performed by unqualified personnel could result in a risk of ...

Page 4: ...onnect the extension cord from the receptacle before disconnecting the product from the extension cord WARNING To reduce the risk of electrocution keep all connections dry and off the ground Do not touch plug with wet hand Wear proper clothing Protect yourself Wear rubber gloves rubber boots etc Wear eye and face protection goggles or face shield Coil cleaning chemicals may cause injuries to the e...

Page 5: ... Quick Connect 7 Spray Nozzles Yellow 15 Fan CJ QDN 15025Y Green Soap Nozzle CJ QDN 2508G 8 8933 ASSEMBLY Chemical Valve Assembly 1 2 3 5 6 4 7 8 90º SPRAY WANDS 8945 24 24 61 cm 8945 36 91 cm 8945 48 48 122 cm 8945 60 60 152 cm 8945 FLEX 24 Flexible 24 61 cm OPTIONAL NOZZLES ACCESSORIES CJ QDN 0003 R Size 3 Pinpoint CJ QDN 90 90 Adapter CJ QDN 45 45 Adapter OTHER ACCESSORIES CJ2 05 115 Motor Pump...

Page 6: ...evel of the pump and squeeze the trigger until a steady flow of water appears 7 When switching between Garden Hose and Tank it is best to re prime the pump 8 Fully open the chemical valve counter clockwise Squeeze the spray gun trigger repeatedly until chemical is primed 9 The COILJET comes with 2 quick connect nozzle attachments Yellow Rinsing Nozzle a 15 fan spray high flow rinsing nozzle Green ...

Page 7: ...0 1 10 GPM 1 5 4 1 liters Pump Positive displacement diaphragm Water Tank 3 3 gallons 12 5 liters Soap Tank 1 75 quarts 1 6 liters Noise Level 66 dBA Dimensions 19 high x 18 wide x 10 deep 48 2 cm x 45 7 cm x 25 4 cm Weight 22 lbs 10 kilos net dry 52 lbs 12 5 liters at 3 3 gallons water and 1 75 quarts 1 6 liters chemical Specifications To use the garden hose water supply turn the knob to the Gard...

Page 8: ...Reset GFCI Motor buzzes but fails to start or does not start at all Problems with pump auto shut off Unit in disuse for extended time Pressure needs to be relieved Contact factory Contact factory Squeeze trigger and relieve pressure water tank not priming air block in the line Prime machine through the garden hose side Prime the tank with the garden hose still attached then take off the garden hos...