Operating Procedure

CAUTION:

 Do not operate this machine without eye protection.

1.  Connect water hose to water inlet of no more than 100 psi. Water supply should be clean. 

Make sure screen washer is in place.

2.  Plug electric cord into an outlet in accordance with the power requirements on the 

nameplate and push the “Reset” button on the GFCI.

3.  Ensure that the two hoses in the footswitch assembly are plugged into the two pneumatic 

switches in the foot pedal compartment. Each side of the footswitch corresponds to a 
different drive direction of the shaft.

4.  Select proper size cleaning tool and fasten onto end of flexible shaft. Never use a tool 

larger than I.D. of tube. 

NOTE:

 Most tubes are rolled at tube sheet. Always measure I.D. 

beyond roll or consult manufacturer’s manual for tube O.D. and gauge.

5.  Position shaft locator on the outside of the flexible shaft so that when the shaft is fully 

inserted in the tube, the entire cleaning tool extends outside the other end of the tube.

6.  Uncoil flexible shaft completely and feed it into the tube. 

DO NOT FORCE SHAFT DOWN 

TUBE.

 Allow machine to do the work. If resistance is felt, back off 2”-3” (50-75mm) and feed 

shaft again until it goes easily. If resistance is too great, use a smaller cleaning tool.

7.  For easiest operation, if possible, insert shaft into tube and keep there for several hours 

before starting in order to remove loops from flexible shaft. 

CAUTION:

 Minimum operating 

radius of flexible shaft is eighteen inches. However, it is recommended that the shaft be 
kept as free from loops as possible. This is especially critical nearest the drive unit.

8.  After completing the job, always unplug machine before disconnecting water supply. 

Running a shaft “dry” may damage the seals. 

CAUTION:

 The SC-TC-60 is designed to be 

used wet or dry — NOT BOTH. It is equipped with a water seal. If used dry, the water seal will 
no longer prevent water leakage.

Forward/Reverse Foot Pedal

• 

The direction the shaft rotates is controlled by the two-way foot pedal.

• 

Clockwise rotation is considered the “Forward” direction

• 

Position the foot pedal like the gas pedal of a car and rock your foot back and forth 
to control direction.

Maintenance & Storage

SC-TC-60

Maintenance

Keep machine clean and dry to maximize performance and longevity. Follow maintenance 
outlined in this manual, such as checking for weak spots, leaks, slices or cuts in hose, replace 
shafts when worn. Additional maintenance details follow in this manual. If the machine 
does not operate properly or has been damaged or exposed to water, call the factory for 
assistance — do not try to service the unit yourself.

Storage

Disconnect water supply line. Disconnect the flexible shaft and drain water to prevent rusting of 
shaft. Do not store machine where residual water in machine may freeze. Refer to Flexible Shaft 
manual for flexible shaft storage.

Summary of Contents for SC-TC-60

Page 1: ...SpeedClean Innovative Maintenance Tools OPERATING MAINTENANCE INSTRUCTIONS MODEL SC TC 60 Tube Cleaner ...

Page 2: ...Storage 7 Troubleshooting 8 Specifications 8 Parts List 9 Plumbing Diagram 10 Accessories 10 Wiring Diagram 11 Warranty Information 12 Thank you for purchasing SpeedClean s SC TC 60 tube cleaning machine We appreciate your business and look forward to serving you in the future As with all SpeedClean products you can be assured that the finest quality components and workmanship have gone into this ...

Page 3: ...safety shoes hard hat and hearing protection are recommended 3 Operational Safety This unit is to be used only by trained operators Keep clear of moving shaft Make sure the shaft will not catch on anything while in use Be sure to select the proper size flexible shaft and tool for the job Do not force the tool Use the correct tool for the application Check flexible shaft for weak or worn condition ...

Page 4: ...EMOVED WITH MOVING PARTS AND ELECTRICAL CONNECTIONS EXPOSED Safety Checklist Do s Keep this manual with the unit at all times Always grasp the plug not the cord when unplugging from AC power Always run clean water through the unit Always secure the unit while transporting to prevent it from damage Store unit indoors in a cool dry area and protect from freezing If the unit is stored in an unheated ...

Page 5: ...n cords are identified by a marking Acceptable for outdoor use store indoors while not in use Do not use damaged extension cords Examine extension cord before using and replace if damaged When using an extension cord be sure to use one large enough to carry the current the product will draw An undersized cord will cause a drop in line voltage resulting in loss of power and overheating If in doubt ...

Page 6: ... Quick Connect Latch 2 Latch Lock 3 Carry Handle 4 GFCI Power Cord 5 Garden Hose Connector 6 Foot Pedal 2 3 4 5 6 Operating Instructions SC TC 60 Pre Operation Checklist Check for adequate water supply Use no smaller than a 5 8 garden hose for water supply Check ground fault circuit interrupter GFCI Test reset Check all connections Connecting Flexible Shaft 1 Select the proper size flexible shaft ...

Page 7: ...ube and keep there for several hours before starting in order to remove loops from flexible shaft CAUTION Minimum operating radius of flexible shaft is eighteen inches However it is recommended that the shaft be kept as free from loops as possible This is especially critical nearest the drive unit 8 After completing the job always unplug machine before disconnecting water supply Running a shaft dr...

Page 8: ... time and or stops GFCI trips won t reset Electrical short to ground Overheated disconnect from power Unit will automatically turn on when cool If GFCI trips often call SpeedClean There may be an unsafe electrical condition Allow unit to cool Motor runs but shaft brush does not turn Problem drive coupler Broken flexible shaft Disconnect power Check drive coupler for damage Replace shaft fittings a...

Page 9: ...er 9 SQC 07 Latch 30 879 Motor Clip 10 SQC 08 Spacer 31 HWW 252 Washer 11 SQC 10 Torsion Spring 32 HWS 0632S 50 Screw 6 32 x 12 EX 007 Rubber Foot 33 HWN 0632 Nut 6 32 13 834R 1 Air Switch 34 HWN 1024 Nut 10 24 14 SC TC LL Latch Lock 35 HWS 1024 163 SC Screw 10 24 x 1 5 8 15 530 122 Strain Relief 36 1234 1 Screw 20 x 1 16 873 Shaft Driver Assembly 37 CV CFCI A GFCI Adapter 17 831 Pulley 2 1 2 38 8...

Page 10: ... SC TC S02 15R 702 Flexible Shaft 25 SC TC S02 25R 702 Flexible Shaft 35 SC TC S02 35R 703 Flexible Shaft 15 SC TC S03 15R 703 Flexible Shaft 25 SC TC S03 25R 703 Flexible Shaft 35 SC TC S03 35R Grit Brush 7 16 5 8 ID SC TC BGB 075 Grit Brush 11 16 3 4 ID SC TC BGB 100 Grit Brush 13 16 1 ID SC TC BGB 125 Brush for 1 ID SC TC BN 1 Brush for 1 2 ID SC TC BN 1 2 Brush for 11 16 ID SC TC BN 11 16 Brus...

Page 11: ...k 2 Motor 1 2 1 NC NC NO NO 2 C 1 115 Volt Ground Ground T8 T5 Wiring Diagram 115V 50 60Hz Wiring Diagram Wiring Diagram 240V 50 60Hz Wiring Diagram SC TC 60 50Hz SC TC 60 L1 NO Red Light Brown Blue 230 Volt Blue White Yellow C C NC NC NO REVERSE L2 CV GFCI 240 VOLT Blue FORWARD WIRING DIAGRAM IRAM 240V 50Hz MOTOR Orange Ground Ground T5 T4 T1 T8 P1 ...

Page 12: ...s machine It is recommended that any repairs be done by SpeedClean as improperly performed repairs will void the warranty For repairs or warranty information DO NOT contact the place of purchase Call SpeedClean Customer Service at 888 700 3540 To obtain warranty service a proof of purchase is required and the unit must be returned freight prepaid This warranty gives you specific legal rights and y...

Reviews: