SC-TC-60
8
Model SC-TC-60 Operating and Maintenance Manual
General Maintenance & Storage
Trouble Shooting
PROBLEM
PROBABLE CAUSE
SOLUTION
Runs in one direction only
• Leak in air control circuit
• Faulty wire connection(s)
• Leak in footswitch air
bellows or air hoses
• Faulty air switch
• Disconnect power. Disconnect
air hoses from air switches to
allow foot pedal bellows to
inflate to full height. Reconnect
and tighten all connections
• Disconnect power.
• Check wiring.
• Switch air hoses to isolate
problem (machine or footswitch)
• Check/replace air switches
Water leaking from base
• Leak in water
circuit plumbing
• Leak at shaft manifold seal
• Disconnect power. Check hoses
and fittings for leaks. Tighten
loose connections.
• Check for leak where drive shaft
enters shaft manifold. Replace
manifold seal.
Runs for short period of
time and/or stops, GFCI
trips/won’t reset
• Electrical short to ground
• Overheated, disconnect
from power. Unit will
automatically turn on
when cool.
• If GFCI trips often call
SpeedClean. There may be an
unsafe electrical condition.
• Allow unit to cool.
Motor runs but shaft/brush
does not turn
• Problem drive coupler
• Broken flexible shaft
• Disconnect power. Check drive
coupler for damage.
• Replace shaft fittings and/
or core.
No water through
flexible shaft
• Problem with water supply
• Inlet screen clogged
• Solenoid valve
not functioning
• Water supply not on, restrictions
in hose or hose too small, water
supply pressure insufficient.
• Remove hose and clean screen.
• Replace solenoid valve,
call Speedclean.
Problem Not Listed, Call Speedclean Customer Service: 1-888-700-3540.
SC-TC-60
Motor
½ HP, 230/115 VAC motor
Power Requirements
230 V 50/60 Hz @ 4.5 A | 115 V 50/60 Hz @ 9.0 A
Rotational speed
860 RPM
Input water connection
¾” standard garden hose
Maximum water pressure
100 psi (7 bar)
Maximum water temperature
140 °F (60 °C)
Specifications