Problem

Possible 

Cause

Solution

Missed 
Timing

Gate battery low

Charge battery

Obstruction to line 
of sight

Ensure clear line of site between 
gate and sensor

Power level too low

Turn power level up

Start/Finish gate not 
set to zero

Set Start/Finish gate as zero for 
gate number

Telemetry not 
configured properly

Ensure Lap counter or RPM 
input options are set correctly to 
match your telemetry system. See 

Connecting the SPMLTT2500

Sensor pointed 
directly at the sun

Avoid configuring the track so 
the sensor is pointed directly into 
the sun

Picking up 
timing when it 
shouldn’t

Power level too high

Turn power level down

Timing gate pointed 
across track

Place timing gate on outside 
section of track

Sensor pointed 
directly at the sun

Avoid configuring the track so 
the sensor is pointed directly into 
the sun

Troubleshooting Guide

Summary of Contents for SPMLTG5000

Page 1: ...1 SPMLTT1000 SPMLTT2500 SPMLTG5000 SPEKTRUM LAP TIMING SYSTEM SPEKTRUM RUNDEN TIMER SYST ME DE CHRONOM TRAGE DE TOURS SPEKTRUM SISTEMA DI CRONOMETRAGGIO SPEKTRUM...

Page 2: ...requires some basic mechanical ability Failure to oper ate this Product in a safe and responsible manner could result in injury or damage to the product or other property This product is not intended...

Page 3: ...SPMLTG5000 Gate system 5 Track Setup 6 Connecting the SPMLTT2500 7 Connecting the SPMLTT1000 8 Installing the SPMLTT2500 on a Surface Vehicle 8 Installing the SPMLTT2500 on a quadcopter 9 Transmitter...

Page 4: ...ype Lap Timing System Gate Dimensions LxWxH 51 x 31 x 16mm Weight 14g IR source 5 individual IR LEDs InputVoltage 3S LiPo Balance Connector Compatibility SPMLTT1000 SPMLTT2500 Connecting a Battery to...

Page 5: ...material available from local hardware stores QTY Materials for vertical PVC gate assembly not included 1 5 foot length of 1 2 inch PVC 6 12 inch sections of 1 2 inch PVC tube 3 1 2 inch PVC T Fittin...

Page 6: ...e between menu points When the numbers displayed are solid the base unit is in the settings menu Use a short press to change values To save settings and exit back to the normal operation mode press an...

Page 7: ...a low voltage mode if the battery voltage drops below 10 volts It will cease operation and begin alternating between L and B on the display to indicated low battery 2 The timing system can also utili...

Page 8: ...e SPMFCF400 paired with the SPMLTT1000 uses the Lap Counter telemetry function delivering the same performance and features as X Bus based systems This combination is the lightest simplest solution to...

Page 9: ...d tape or adhesive backed hook and loop material The IR receiver must face the IR LEDs as the vehicle passes the timing gate IMPORTANT The IR receiver sensor must point toward the timing gate as it pa...

Page 10: ...he sensor is connected to an RPM input IMPORTANT Select RPM when using the SPM4649T telemetry receiver with the SPMLTT2500 4 To log lap times onto an SD card determine the le name and change the optio...

Page 11: ...nsure Lap counter or RPM input options are set correctly to match your telemetry system See Connecting the SPMLTT2500 Sensor pointed directly at the sun Avoid configuring the track so the sensor is po...

Page 12: ...lacement decisions are at the sole discretion of Horizon Proof of purchase is required for all warranty claims SERVICE OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE PURCHASER S SOLE AND EXCLUS...

Page 13: ...deration Be sure your name address and RMA number are clearly written on the outside of the shipping carton NOTICE Do not ship LiPo batteries to Horizon If you have any issue with a LiPo battery pleas...

Page 14: ...relevant provisions of the EMC directive A copy of the EU Declaration of Conformity is available online at http www horizonhobby com content support render compliance Instructions for disposal of WEE...

Page 15: ...SM is a registered trademark of Horizon Hobby LLC The Spektrum trademark is used with permission of Bachmann Industries Inc All other trademarks service marks and logos are property of their respectiv...

Reviews: