118142-001 Rev B
Page 104 of 104
6.8 SERIAL COMMAND HANDLING
6.8.1 Command Time Out
The host computer should set a serial time
out at approximately 100mS. This allows the DSP to process the incoming
message, and transmit a response. The DSP will initiate a reply to
incoming messages in approximately 1-2mS, with a worst case of 5mS.
6.8.2 Buffer
Flushing
The DSP will flush the incoming serial data buffer every time an STX is
received. This provides a mechanism to clear the receive buffer of partial
or corrupt messages.
6.8.3 Handshaking
The only handshaking implemented on the host interface, is built in to the
implementation of this protocol. That is, the host must initiate all
communications. If the supply receives a program command, an
acknowledge message is sent back to the host via the “$” message. If the
host does not receive an acknowledge within the time out window, the
host should consider the message lost or the device off-line.
Similarly, if the supply receives a request command, the requested data is
sent back to the host. If the host does not receive the requested data
within the time out window, the host should consider the message lost or
the device off-line.
This essentially uses the full-duplex channel in a half-duplex
communication mode.
Summary of Contents for DXM100 Series
Page 11: ...DXM100 MANUAL 5 118147 001 Rev D Figure 2 1 Unit Dimensions ...
Page 16: ...DXM100 MANUAL 10 118147 001 Rev D Figure 3 3 Local Programming Via External Voltage Source ...
Page 17: ...DXM100 MANUAL 11 118147 001 Rev D Figure 3 4 Remote Monitoring ...
Page 18: ...DXM100 MANUAL 12 118147 001 Rev D RELAY Figure 3 5 Enable Interlock Logic Control ...
Page 37: ...118142 001 Rev B Page 13 of 104 Figure 9 Web Page 1 Contact Information ...