118165-001 REV. A
475 Wireless Boulevard • Hauppauge, New York 11788, USA • www.spellmanhv.com • T:+1 631.630.3000 • F:+1 631.435.1620
61
<ARG10> More than 2 starts requested in a 60 second period. (1 =
Fault, 0 = No Fault).
<ARG11> HSS Miswire Fault. The Wiring for the Tube Rotor
between the Tube and PMX is incorrect. See the following
table:
Note: P = Phase Wire, R = Run Wire, C = Common Wire.
<ARG12> Not Used, for future expansion, will Read as 0.
<ARG13> HSS Communication Fault. The serial link between the
control board and the HSS has failed. If this bit reads as “1”
(Faulted) the control board was not able to communicate with the
HSS to retrieve the status. Since the control board could not get the
status from the HSS the values of ARGs 1-11 are not known. They
will report as “0” but may in fact be faulted. Note that this serial link
is not used in regular operation, and is only used to retrieve the
detailed fault status. If the link fails the unit will still continue to
function normally, with the exception of getting expanded status
using this command.
Notes:
The expanded HSS faults are cleared along with the rest of
the faults by the “Reset Faults” command, however if the condition
causing the fault is still present, it may immediately fault again.
Mis-wire detection is done at the beginning of run mode. The
wiring may be incorrect, but no fault will be detected until the HSS
is actually turned on.
Miswire
fault code
Miswire fault condition
0
Normal operation, Wiring is Correct
1
Phase wire in Run slot AND
(Run wire in Phase slot OR
Run wire in Common slot and
Common wire in Phase slot).
2
Phase wire in Common slot AND
(Common wire in Phase slot OR
Common wire in Run slot and
Run wire in Phase slot).
3
Run wire in Common slot and
Common wire in Run slot.