ARG1 = +15V, the output of the regulated 15V supply.
ARG2 = -15V, the output of the regulated -15V supply.
ARG3 = +24V, the output of the reg24V supply.
ARG4 = 3.3Va, the output of the regulated 3.3V supply.
ARG5 = 3.3Vb, monitors same voltage as ARG4 (see note1)
ARG6-ARG8 are not used currently.
ARG9 = The monitored Voltage across the Tube Filament.
ARG10 = The monitored High Voltage output of the supply.
ARG11 = The monitored output current of the supply.
ARG12 = The monitored DC input line voltage to the supply.
ARG13 = The monitored Filament Leak current.
ARG14 = The monitored current through the filament.
ARG15 = Ground Voltage Offset (This actually measures the offset
error of the A/D converter rather than an actual voltage).
Scaling Summary Table
ARG Function
Range
Scaling/Bit
1
+15V
0 – 25.5V
0.0062256V / Bit
2
-15V
(note1)
-16.466V – 0V
Use Equation:
Voltage = Arg*0.0043663
– 16.4665V
3
+24V
0 – 42.9V
0.0104762V / Bit
4
3.3V(a)
(note 2)
0 – 12.73V
0.00310847V / Bit
5
3.3V(b)
(note 2)
0 – 4.906V
0.0011978V / Bit
9
Filament
Voltage
0 – 11.78V
0.0028766V / Bit
10
kV
Feedback
(note 3)
0 – 53476V
13.059V / Bit
11
mA
Feedback
(note 3)
0 – 213.828
0.052217mA / Bit
12
DC Voltage
0 – 346.4V
0.084596V / Bit
13
Leak Limit
0 – 106.9mA
0.0261mA / Bit
14
Filament
Feedback
0 – 6.415A
0.0015665A / Bit
15
GND
Monitor
0 - 3V
0.7326 mV / Bit
Notes: