SL SERIES MANUAL
13
118006-001 REV T
+
Remote
1
2
3
4
5
6
7
8
9
10
11
Current
Program
V
V
Remote
Voltage
Program
+
Remove jumpers for
remote programing
Voltage Source 0-10V = 0-100% of Rated Output
It is recommended that analog signals be isolated
via isolation amplifiers.
All cables should be shielded with the shields
being returned to the chassis ground of the
High Voltage Power Supply.
TB1/J5
PS Common
Z in = 10M
Ω
Z in = 10M
Ω
Figure 3.2A -- Wiring Diagram for Remote Programming Via Voltage
1
2
3
4
5
6
7
8
9
10
11
Remote
Current
Control
Remote
Voltage
Control
Z in = 10M
Z in = 10M
Remove jumpers for
remote programing
All cables should be shielded with the shields
being returned to the chassis ground of the
High Voltage Power Supply.
TB1/J5
20k
Ω
20k
Ω
Ω
Ω
CW
CW
+10.32V
1mA max.
PS Common
Fully Counterclockwise = Zero Output
Fully Clockwise = 100% of Rated Output
If connections to external potentiometers are
excessively long (>10ft), motorized
potentiometers are recommended.
Figure 3.2B -- Wiring Diagram for Remote Programming Via External