SL2KW SERIES MANUAL
13
118088-001 REV C
Z out = 4.99k ohms ±0.1%
Z out = 4.99k ohms ±0.1%
It is recommended that analog signals be isolated via
isolation amplifiers.
All cables should be shielded
with the shield being returned to the chassis ground
of the high voltage power supply.
-
2
+
6
7
5
4
3
M
J5
1
PS Common
Voltage
Monitor
+
Current
Monitor
M
-
Figure 3.3 – Remote Monitor Test Point Designations
J5
S2
S1
All cables should be shielded
with the shields being returned
to the chassis ground of the
High Voltage Power Supply.
Remove jumpers for
remote programing
15
17
16
14
S2 = Remote High
Voltage On
S1 = Remote High
Voltage Off
S1 must be closed to enable HIGH VOLTAGE.
Momentary closure of S2 will enable HIGH
VOLTAGE ON.
Opening S1 will disable HIGH VOLTAGE ON and
switch the unit to the HIGH VOLTAGE OFF mode.
I
t is recommended to use relay contacts
for S1 and S2. Relays should be located
as close as possible to the high voltage
power supply. Coils should be driven
from isolated sources. Signals are at
15Vdc, 25mA max., and are only to be
used for contact closure.
Figure 3.4 – Remote Control of High Voltage ON and High Voltage OFF Interface