6.6.16 Program Local/Remote Mode
Description:
The host requests that the firmware to switch between Local and Remote
Mode.
Direction:
Host to supply
Syntax:
<STX><99><,><ARG><,><CSUM><ETX>
Where:
<ARG> 1 = Remote, 0 = Local in ASCII format
Example:
<STX>99,1,<CSUM><ETX>
Response:
<STX><99><,><$><,><CSUM><ETX>
<STX><99><,><ARG><,><CSUM><ETX>
where <ARG> = error code
Error Codes TBD,
1 = out of range
118080-001 REV A
Page 87 of 95
Summary of Contents for SLM SERIES
Page 15: ...SLM MANUAL 6 118073 001 Rev C Figure 2 2 Unit Dimensions 1200W ...
Page 19: ...SLM MANUAL 10 118073 001 Rev C Figure 3 3 Local Programming via External Voltage Source ...
Page 20: ...SLM MANUAL 11 118073 001 Rev C Figure 3 4 Remote Monitoring ...
Page 40: ...Figure 9 Web Page 1 Contact Information 118080 001 REV A Page 13 of 95 ...
Page 98: ...Request Faults 68 20 ASCII 118080 001 REV A Page 71 of 95 ...