5.5.23 Request unit Scaling
Description:
The host requests that the firmware report the unit scaling.
Direction:
Host to supply
Syntax:
<STX><28><,><ETX>
Example:
<STX>28,<ETX>
Response:
<STX><28><,>< ARG1><,>< ARG2><,><ETX>
Where:
<ARG1> =0-65535 in ASCII format representing the voltage full-scale
value.
<ARG2> =0-65535 in ASCII format representing the current full-scale
value.
Example:
<STX>28, 7000, 856<ETX>
Voltage full scale = 70.00kV
Current full scale = 8.56mA
118080-001 REV A
Page 62 of 95
Summary of Contents for SLM SERIES
Page 15: ...SLM MANUAL 6 118073 001 Rev C Figure 2 2 Unit Dimensions 1200W ...
Page 19: ...SLM MANUAL 10 118073 001 Rev C Figure 3 3 Local Programming via External Voltage Source ...
Page 20: ...SLM MANUAL 11 118073 001 Rev C Figure 3 4 Remote Monitoring ...
Page 40: ...Figure 9 Web Page 1 Contact Information 118080 001 REV A Page 13 of 95 ...
Page 98: ...Request Faults 68 20 ASCII 118080 001 REV A Page 71 of 95 ...