81233-4r1
Page 5 of 9
4 Environmental conditions
4.1
Operating
Protection:
The power supply will be designed to meet IP40 and will be reasonably protected
against dust.
Temperature:
+5
C to +40
C.
Relative Humidity: 20% to 80% (no condensation)
4.2
Storage
Temperature:
-40
C to +70
C.
Relative humidity:
5% to 95%
Absolute humidity:
maximum 25 gm
-
³
Maximum storage period: >0.25 year (at above conditions)
Long term storage:
>3 year (special packaging required)
5 Mechanical
5.1
Mechanical outline:
185mm x 105mm x 33.5mm
The mass of the module is nominally 2kg
105.0
33
.5
185.0
66
.5
9.7
30
.0
23.7
46.0
14.7
15w D-plug
HOLE Ø4.5mm
IN 3 POSITIONS
MOUNTING HOLE TEMPLATE
VIEWED FROM THE TOP OF UNIT
(NOTE-Max thread depth into unit is M4x7mm)
Unit Footprint
Fixing Face
TOP OF UNIT
Pr
e-
hea
t
Fil / C
urre
nt
Lim
it
Em
ission
HV
Filament
HV
71192rA