background image

17

Figure 1. Half Mask Facepiece

Summary of Contents for Surviair 2000 Series

Page 1: ...ng it into service Please refer to the inspection procedures in this manual Failure to comply with this warning may result in personal injury illness or death NIOSH APPROVED SEE SEPARATE APPROVAL LABE...

Page 2: ...vels SPERIAN cannot predict what will happen to this respirator in every potential environment Materials can be chemically attacked if exposed to the wrong environment and may exhibit excessive corros...

Page 3: ...1910 134 Appendix C Medical Evaluation Questionnaire or by a medical professional Persons sensitized can have a severe reaction to chemicals at levels well below accepted health levels such as the OSH...

Page 4: ...t edition If this respirator will be used during welding it is the user s responsibility to obtain the proper equipment for protection against sparks optical radiation and impact This respirator will...

Page 5: ...efore using a particulate filter you must confirm the atmosphere is non IDLH and not oxygen deficient the contaminant is a particulate hazard and you must determine the hazard ratio hazard concentrati...

Page 6: ...osphere if one or more of the ESLIs is gray 3 Cartridge Filter Installation a Ensure that you have the correct cartridge and or filter type for the contaminants in your work area If you are not sure c...

Page 7: ...ts Hand tighten but do not overtighten See inset 1 3 Position the bottom of the facepiece as low as possible under the chin while positioning the narrow portion of the facepiece on the bridge of the n...

Page 8: ...as a thin sheet of plastic or rubber When the respirator is equipped with cartridges filter retainers may be used as an aid Alternatively the cartridges may be removed to perform the fit check If remo...

Page 9: ...this warning may lead to personal injury illness or death E CHEMICAL CARTRIDGE SERVICE LIFE AND REPLACEMENT WARNING OSHA allows the use of respirators for protection against contaminants with poor wa...

Page 10: ...ow to determine the cartridge service life for mixtures please contact SPERIAN Failure to comply with this warning may lead to personal injury illness or death The gas vapor service life depends on th...

Page 11: ...in the filter resulting in a loss of filter efficiency and the determina tion of when breathing resistance becomes too uncomfortable is subjective Filters should also be replaced in accordance with s...

Page 12: ...it from the facepiece for inspection 1 Inspect the facepiece skirt for cuts gouges punctures tears nicks and deterioration from age heat or contamination and the face seal area for distortion 2 Inspe...

Page 13: ...nt type cleaners to clean any part of the respirator Do not use sonic cleaners on respirators equipped with a speaking dia phragm a Remove the cartridges and or filters b Immerse the facepiece in warm...

Page 14: ...g the stem through the seat until it snaps into place 6 Reinstall the exhalation valve cover 7 Test the new valve by performing a negative pressure fit check as described in section C I STORAGE WARNIN...

Page 15: ...4 Lower Headband Blue 1 140040 Lower Headband and Upper Cradle Set Blue 1 2 See Note Facepiece Skirt Series 2000 2a See Note Facepiece Skirt Blue 1 w Speaking Diaphragm 2b See Note Facepiece Skirt Blu...

Page 16: ...anic Vapors 14 100200 Acid Gases 14 100300 Organic Vapors and Acid Gases 14 100400 Ammonia and Methlyamine 14 100600 Mercury Vapor and Chlorine 14 100800 Multi Contaminant 15 1051 Combination Organic...

Page 17: ...17 Figure 1 Half Mask Facepiece...

Page 18: ...f defective parts and such other necessary maintenance and repair as may be required Normal wear and tear parts damaged by abuse misuse negligence or accidents and inhalation and exhalation valves are...

Reviews: