SURVIVAIR Opti-Fit
™
Convertible Facepiece
24
Figure 18. Blower Inlet Gasket
2. Install a SPERIAN HE Filter, P/N 108000,
and hand tighten. A SPERIAN shower
cap, P/N 981177, may be fitted over the
filter inlet.
b. Belt-mounted PAPR Configuration–
Cartridge and Filter Installation
WARNING
● Always read cartridge labels prior
to use to be certain that you have
cartridges and/or filters that will
provide the required protection. Fil-
ters labeled for protection against
particulates only shall not be used
for gases/vapors, and cartridges la-
beled for protection against gases
and vapors only shall not be used
for particulates.
● Only use three (3) cartridges or filters
of the same type.
● Never use the PAPR without all four
(4) blower inlet gaskets in place (Fig-
ure 19). Use of the PAPR without the
blower inlet gasket could allow con-
taminants to leak into the facepiece.
● FAILURE TO COMPLY WITH THIS
WARNING MAY LEAD TO PERSON-
AL INJURY, ILLNESS, OR DEATH.
1. Verify that the rubber gaskets are in place
at the bottom of the threaded blower inlets
as shown in Figure 19.
Figure 19. Blower Inlet Gaskets
2. If installing chemical cartridges, remove the
screw cap and plug from each cartridge.
Retain for reuse.
3. Install the three (3) cartridges or filters and
hand tighten.
4. Connect the power cord between the blower
and battery pack.
3. Pre-operational Flow Check
a. Mask-mounted PAPR Configuration–Pre-opera
-
tional Flow Check
WARNING
Flow check, facepiece fit check, don
-
ning, and doffing must be done in a safe,
uncontaminated area. Failure to comply
with this warning may lead to personal
injury, illness, or death.
The airflow must be verified before each use.
Use the following procedure to verify that the
blower is supplying adequate airflow.
1. Detach the blower from the facepiece by
pressing down the catch on top of the
blower and pulling the blower away from
the facepiece. See Figure 20.
Figure 20. Blower Catch
2. Connect the power cord to the battery pack
and blower assembly and start the blower
by pressing the battery ON/OFF switch.
3. With the blower outlet facing upward, in-
sert the Flow Meter, P/N 580009, with the
arrow pointing upward, being careful not
to cover the slots in the side of the flow
meter tube. See Figure 21.