Instruction manual for compressor type HLF2/77
Page 12
FAULT TRACING CHART
1. Compressor capacity is low, or the compressor is not delivering full pressure
Possible causes
Remedy
Dirty, damaged or worn valves.
Clean and check all valve plates, springs and
gaskets. Replace defective parts.
Carbon deposits on valves.
Piston rings are worn. Replace.
Unsuitable lubricating oil. Change oil brand.
Piston rings are stuck.
Loosen and remove piston rings.
Clean piston ring grooves and rings.
Air filter clogged.
Clean filter.
Air leaking to surroundings or leaking inside the
compressor through valve gaskets and valve
plates.
Check for external leakages with soapy water.
Check valve gaskets and valves.
Faulty automatic control equipment.
Inspect components and circuits.
2. Safety
valve
blows
Possible causes
Remedy
Closed air line valve.
Open the valve.
Carbon deposits in non-return valve.
Clean the valve.
Faulty adjustment of automatic system.
Compressor does not stop when air reservoir is
full.
Check pressure switch and automatic circuitry.
Safety valve damaged or defective (causing it to
open at lower pressure).
Replace safety valve.
3. Valves require maintenance too frequently
Possible causes
Remedy
Overheating.
High ambient temperature. Improve fresh air
supply. Carbon deposits in coolers. Clean
coolers.
Dirt or foreign matter in intake air.
Air filter damaged. Improve suction air quality.
Cooler tubes dirty.
Clean.
4. Bearings and bearing housings running hot. Lub. oil overheating. Noise from bearings
Possible causes
Remedy
Damaged or worn bearings.
Replace bearings.
Uneven wear on crankshaft bearings.
Check crankshaft for straightness.
Low oil level.
Refill lub. oil.
5. Piston running hot
Possible causes
Remedy
Worn bearing on flywheel end.
Check little end bearing, piston rings and piston
clearance.
Piston and/or rings binding in cylinder.
Ensure cool fresh air supply to cooling fan and
suction air filter. If the piston has completely
seized, wait a while before turning over the
compressor. Clean cylinder and piston, fit new
piston if necessary.
CCG DOC NO. 346055
Summary of Contents for HLF2/77
Page 1: ...HLF2 77 INSTRUCTION MANUAL AIR COMPRESSOR GB SPERRE CCG DOC NO 346055 ...
Page 4: ...Instruction manual for compressor type HLF2 77 Page 3 CCG DOC NO 346055 ...
Page 18: ...CCG DOC NO 346055 ...
Page 19: ...CCG DOC NO 346055 ...
Page 20: ...CCG DOC NO 346055 ...
Page 21: ...CCG DOC NO 346055 ...
Page 22: ...CCG DOC NO 346055 ...