Instruction manual for compressor type HLF2/77
Page 8
Coolers
To ensure trouble-free operation it is of the greatest importance to ensure that the coolers are kept
clean and free of foreign matter at all times. If the coolers are not kept properly clean, high air
temperatures will result, with a consequent reduction of working life of valves and cylinders.
The coolers can be externally cleaned by spraying on a good grease solvent and then blowing them
clean with compressed air.
In the case of heavy deposits of dirt the coolers should be dismantled for external and internal
cleaning.
Any carbon deposits in the tubes can be removed by placing them in a bath of carbon remover or
similar solvent overnight, and then flushing with hot fresh water.
Important: Make sure that the cleaning products are suitable for use on copper pipes.
Gaskets
In order to achieve satisfactory operation it is recommended to replace gaskets at every overhaul.
Worn or damaged gaskets will reduce compressor capacity and cause faulty operation.
Use only original SPERRE gaskets.