DC Current
Overload Protection:
0.5A/250V fuse on mA inputs
10A for 60 seconds on 10A input (unfused)
Resistance
Overload Protection:
250VDC or peak AC – Electronic (No fuse blow).
4
Range
Resolution
Accuracy (18°C to 28°C)
Full Scale
Burden Voltage
2mA
1µA
±(1.0% of rdg + 4d)
0.25V
200mA
100µA
"
"
10A
10mA
±(3.0% of rdg + 1d)
1.2V
AC Current
(50Hz-500Hz)
Overload Protection:
0.5A/250V fuse on mA inputs
10A for 60 seconds on 10A input (unfused)
Range
Resolution
Accuracy (18°C to 28°C)
Full Scale
Burden Voltage
2mA
1µA
±(1.0% of rdg + 4d)
0.25V
200mA
100µA
"
"
10A
10mA
±(3.0% of rdg + 1d)
1.2V
Range
Resolution
Accuracy (18°C to 28°C)
Open Circuit
Voltage
200
10mΩ
±(1.2% of rdg + 4d)
0.45V
2K
1Ω
±(1.2% of rdg + 1d)
"
20K
10Ω
"
"
200K
100Ω
"
"
2000K
1KΩ
"
"
20M
10KΩ
±(3.0% of rdg + 5d)
"
Diode Check
Overload Protection:
250VDC or peak AC – Electronic (No fuse blow).
Range
Test Current
Open Circuit Volts
DCV 2V
0.3mA appox.
1.5Vdc
Continuity
Overload Protection:
250VDC or peak AC - Electronic ( No fuse blow).
Range
Resolution
Audible Indication
Open Circuit Volts
2KΩ
1Ω
<1KΩ
0.45V
DM4400 04_06 5/3/06 1:10 PM Page 7