Functional Buttons

 

Display Symbols 

BUTTON

OPERATION PERFORMED

 

HOLD/LIGHT Button

Press and hold for 2 seconds to turn the display backlight on or off

HOLD/LIGHT Button

Press to step through the available functions

Select Button

Press to step through the available functions.

RANGE

• Press RANGE to enter the manual ranging mode; the Meter beeps
• Press RANGE to step through the ranges available for the selected function; the Meter beeps
• Press and hold RANGE for 2 seconds to return to autoranging; the Meter beeps

MAX/MIN

Press to select the maximum or minimum value. Press and hold to exit.

REL 

• Press to enter REL mode
• Press again to exit REL mode

Data hold is active

Sleep Mode 

Negative reading

AC

AC measurement 

DC

DC measurement

AUTORANGE

Auto ranging mode

OL

The input value is too large for the selected range 

Test of diode

The continuity buzzer is on.

Maximum and Minimum reading.

The battery is low.
       Warning: To avoid false readings, which could lead to possible electric shock or personal injury,  

replace the battery as soon as the battery indicator appears .

Sensor test is in progress

The REL is on to display the stored value minus the present value

Ω

: Ohm. The unit of resistance

k

Ω

: kilohm. 1 x 10

3

 or 1000 ohms

M

Ω

: Megaohm. 1 x 10

6

 or 1,000,000 ohms

V: Volts. The unit of voltage
mV: Millivolt. 1 x 10

-3

 or 0.001 volts.

A: Amperes (amps). The unit of current
mA: Milliamp. 1 x 10

-3

 or 0.001 amperes

µA : Microamp. 1x 10

-6

 or 0.000001 amperes

F: Farad. The unit of capacitance
µF : Microfarad. 1 x 10

-5

 or 0.000001 farads.

nF : Nanofarad. 1 x 10

-9

 or 0.000000001 farads.

Hz: Hertz. The unit of frequency in cycles/second.
kHz: Kilohertz. 1 x 10

3

 or 1,000 hertz.

MHz: Megahertz. 1 x 10

6

 or1 ,000,000 hertz.

NCV

Non-Contact Voltage measurement

Summary of Contents for DM6650T

Page 1: ...ave AC DC Voltage Capacitance Test AC Alternating Current Hz Frequency and Duty Cycle Test DC Direct Current mA Millamp Ohm Resistance A Amp Diode Test NCV Non Contact Voltage Sensing Continuity Test...

Page 2: ...g mode OL The input value is too large for the selected range Test of diode The continuity buzzer is on Maximum and Minimum reading The battery is low Warning To avoid false readings which could lead...

Page 3: ...may cause sparking which can lead to an explosion Never use the instrument if its surface or your hand is wet Do not exceed the maximum allowable input of any measuring range Never open the battery co...

Page 4: ...rect current AC DC Selectable Alternating Current Direct Current Earth ground Terminal The equipment is protected throughout by double insulation or reinforced insulation Application around and remova...

Page 5: ...stated below Input Amplitude DC electric level is zero lnputAmplitude rangeX30 Frequency response 1kHz NOTE If the value of current to be measured is unknown use the maximum measurement position and...

Page 6: ...F CAPACITANCE MEASUREMENT See Figure 7 To measure capacitance connect the Meter as follows 1 Insert the red test lead into the input terminal and the black test lead into the COM terminal 2 Set the ro...

Page 7: ...mum values This sets the display to show high MAX and low MIN readings The Meter enters the manual ranging mode after pressing MAX MIN button Press and hold MAX MIN for over 2 seconds to exit the MAX...

Page 8: ...n 15 minutes AC CURRENT RANGE RESOLUTION ACCURACY 600 A 0 1 A 1 2 5 6000 A 1 A 60mA 0 01mA 1 5 5 600mA 0 1mA 6A 0 001A 2 0 5 10A 0 01A When 5A Continuous measurement is allowed When 5A Continuous meas...

Page 9: ...hen the fuse test has been completed disconnect the connection between the testing leads and the circuit under test and remove the testing leads from the input terminals of the Meter C Replacing the F...

Page 10: ...ts original purchasers in connection with the sales of Sperry products provided that such products shall not have been altered by the distributor The distributor shall be fully responsible for any war...

Reviews: